Cummins
Cummins
20KW Cummins Marine Generator 30KW 50KW
20KW Cummins Marine Generator 30KW 50KW

20KW Cummins Marine Generator 30KW 50KW

Product Introduction

♦ Designed for professional maritime use, these marine generators for sale provide reliable power for navigation, communication, and auxiliary systems on vessels of various sizes and operational demands.

 

♦ Equipped with efficient Cummins diesel engines, the marine generator for sale ensures optimized fuel consumption and stable load response, supporting continuous and standby power needs in harsh marine environments.

 

♦ Offering modular design and remote monitoring capabilities, these marine generators deliver low maintenance, enhanced operational reliability, and compliance with maritime safety regulations for commercial and recreational vessels.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Marine Generator Technical Parameters
Genset Model Genset Power(KW) Genset Power(KVA) Engine Brand Engine Model Engine Power(KW) Frequency and Speed Cylinders Size (L*W*H)mm Weight(KG)
AT-40GFM 40 50.00  Cummins 4BTA3.9-GM47 47 50Hz/1500RPM  60Hz/1800RPM 4 1670X850X1270 800
AT-50GFM 50 62.50  Cummins 6BT5.9-GM83 83 6 1900X900X1300 1000
AT-64GFM 64 80.00  Cummins 6BT5.9-GM83 83 6 1900X900X1300 1100
AT-75GFM 75 93.75  Cummins 6BTA5.9-GM100 100 6 1900X900X1300 1250
AT-90GFM 90 112.50  Cummins 6BTA5.9-GM100 100 6 2020X900X1300 1300
AT-100GFM 100 125.00  Cummins 6CT8.3-GM115 115 6 2080X900X1360 1650
AT-120GFM 120 150.00  Cummins 6CT8.3-GM115 115 6 2120X900X1360 1700
AT-150GFM 150 187.50  Cummins 6CTA8.3-GM155 155 6 2220X1000X1790 1720
AT-1560GFM 160 200.00  Cummins 6LTAA8.9-GM200 200 6 2250X1000X1790 1750
AT-200GFM 200 250.00  Cummins N855-DM 240 6 2760X1000X1790 2700
AT-250GFM 250 312.50  Cummins N855-DM 284 6 2760X1000X1790 2800
AT-280GFM 280 350.00  Cummins N855-DM 317 6 2998X1000X1790 2950
AT-300GFM 300 375.00  Cummins K19-DM 358 6 2998X1000X1790 3360
AT-350GFM 350 437.50  Cummins K19-DM 410 6 3170X1000X1920 3480
AT-400GFM 400 500.00  Cummins K19-DM 448 6 3170X1000X1920 3650
AT-680GFM 680 850.00  Cummins K38-DM 746 12 4050X1500X2480 7200
AT-800GFM 800 1000.00  Cummins K38-DM 880 12 4100X1500X2480 7350
AT-1000GFM 1000 1250.00  Cummins K50-DM 1097 16 4500X1500X2480 9500

 

Functional Positioning and Target Users for Marine Generators

This marine generator range from Cummins targets professional users requiring dependable onboard power systems on vessels. Designed for shipbuilders, fleet operators, and marine engineers, the marine generators for sale provide consistent electrical supply for critical functions including navigation, communication, and vessel lighting. The units accommodate various vessel sizes and operational profiles, supporting both continuous and standby power demands. Their rugged construction caters to commercial shipping, offshore platforms, and luxury yachts, where reliability under harsh environmental conditions is crucial for operational safety and regulatory compliance.

Technical Features and Measurable Specifications of Marine Generators

These marine generators incorporate Cummins marine-grade diesel engines paired with high-efficiency alternators, offering rated outputs of 30 kW and 50 kW. Fuel consumption metrics are optimized, with measured values of 5.88 L/h and 9.80 L/h respectively at full load, ensuring economical operation. Configurable control systems enable remote monitoring and control via mobile applications and dedicated software. Available enclosure options include open frame, sound-attenuated, and containerized housings tailored to vessel spatial constraints. This product line adheres to international standards, assuring durability against salt exposure, vibration resilience, and stable load response under variable operating conditions.

Industry Applications and Real-World Value of Marine Generators

The marine generators offered are integral to vessel electrical architectures across multiple maritime sectors. They fulfill essential roles in onboard power generation for primary propulsion auxiliaries, emergency backup systems, and communication networks. Their compatibility with automated shore power systems and remote diagnostics enhances operational efficiency and safety in commercial shipping, offshore drilling operations, and recreational boating. The provision of flexible voltage configurations and customized enclosures allows seamless integration into complex marine systems, reducing downtime and maintenance overhead while ensuring compliance with maritime regulatory frameworks.

 

 

FAQ Section

1.What is the typical lead time for ordering the Cummins Marine Generator 30KW/50KW?

We generally require a lead time based on production schedules and order volume. Typical delivery times vary but are optimized through our streamlined manufacturing process. For precise timelines on our marine generators for sale, please contact us directly with your project details.

2.Can you customize the marine generator to fit specific vessel voltage or enclosure requirements?

Yes, we offer flexible customization for our marine generator products, including various voltage settings, enclosure types (open frame, sound-attenuated, containerized), and control systems. Our technical team works with you to meet vessel-specific electrical and spatial needs.

3.What are the fuel consumption rates of the Cummins Marine Generator at different loads?

At full load, fuel consumption is about 5.88 L/h for 30KW and 9.80 L/h for 50KW. At 75% load, rates drop to 4.41 L/h and 7.35 L/h, respectively, and at 50% load, 2.94 L/h and 4.90 L/h. These figures ensure efficient operation and help minimize overall fuel costs on board.

4.How do you support installation and maintenance for your marine generators?

We provide guidance and technical support for installation and commissioning of our marine generators for sale. Our global service network ensures availability of spare parts and maintenance services, enabling reliable operation and minimizing downtime throughout the generator’s service life.