Cummins
Cummins
100KW Cummins Diesel Generator 120KW 150KW 160KW
100KW Cummins Diesel Generator 120KW 150KW 160KW

100KW Cummins Diesel Generator 120KW 150KW 160KW

Product Introduction

♦ This series of Cummins diesel generator sets covers a power range of 100KW to 160KW (including 120KW and 150KW), featuring original Cummins engines with strong power, low fuel consumption, and clean emissions. Ideal for construction, factories, data centers, and standby power applications.


♦ Available in 100KW, 120KW, 150KW, and 160KW configurations. Designed with four-stroke, direct injection, and water cooling. Includes a brushless self-excited alternator and intelligent control panel with overload, low oil pressure, and high temperature alarms. Supports manual or ATS auto transfer switching.


♦ Whether for 100KW commercial power supply, 150KW construction site power, or 160KW emergency backup, this series delivers efficient performance. The durable Cummins engine offers low maintenance costs, with open or soundproof enclosure options. Reliable power for telecom base stations, hospitals, farms, and more.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Cummins-Diesel Generator  Technical Parameters
Genset Model AT-80GFS AT-90GFS AT-100GFS AT-110GFS AT-120GFS AT-130GFS AT-140GFS AT-150GFS
Genset Power KW(=0.8KVA) 80 90 100 110 120 130 140 150
KVA(=1.25KW) 100 112.5 125 137.5 150 162.5 175 187.5
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 15.69  17.65  19.61  21.57  23.53  25.49  27.45  29.41 
75% Load (L/h) 11.76  13.24  14.71  16.18  17.65  19.12  20.59  22.06 
50% Load (L/h) 7.84  8.82  9.80  10.78  11.76  12.75  13.73  14.71 
Fuel Tank Capacity (L) 100 100 100 160 160 160 200 200
Open Type
(L*W*H)
Demension(mm) 2250*800*1450 2250*900*1500 2250*900*1500 2300*950*1500 2300*950*1500 2300*950*1500 2400*1050*1600 2400*1050*1600
Weight(KG) 980 1050 1100 1200 1300 1400 1600 1700
Silent Type
(L*W*H)
Demension(mm) 2600*1100*1500 2800*1100*1500 2800*1100*1500 2800*1100*1500 2900*1100*1700 2900*1100*1700 2900*1100*1700 3000*1100*1700
Weight(KG) 1380 1450 1500 1600 1700 1800 2000 2100
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material Cast iron, stainless steel, galvanized...

 

Eco-Friendly Emission Standard with High-Pressure Common Rail & SCR Aftertreatment
This 100KW, 120KW, 150KW and 160KW Cummins diesel generator is equipped with high-pressure common rail fuel injection system and professional SCR aftertreatment device. As a high-performance diesel generator driven by genuine Cummins engine, it fully complies with China Non-Road Stage IV and Euro V emission standards, realizing low emission, low pollution and green and clean operation. The optimized combustion control and exhaust treatment technology effectively reduce harmful gas emissions, making the Cummins diesel generator suitable for environmentally restricted areas and compliant industrial projects.

 

Dual Cooling Circuit Design for Efficient Heat Dissipation
Featuring an independent dual cooling circuit structure, this heavy-duty Cummins diesel generator separates high-temperature and low-temperature areas for targeted heat dissipation. This innovative design boosts overall heat dissipation efficiency by 18%, effectively lowering operating temperature and preventing overheating under high-load and harsh working conditions. With the reliable power output of Cummins core components, the diesel generator maintains stable long-duration operation, extends service life, and delivers outstanding environmental adaptability in high-temperature and continuous working scenarios.

 

Factory Integrated Parallel ATS Cabinet for Intelligent Power Switching
This premium Cummins diesel generator comes with original factory integrated parallel ATS cabinet as standard configuration. It eliminates the need for third-party control equipment and realizes seamless automatic switching between mains power and generator power supply. The integrated control system ensures precise, safe and fast power conversion, greatly improving the intelligence and stability of power supply. Covering 100KW to 160KW power range, this industrial-grade diesel generator simplifies on-site installation and commissioning, and is an ideal reliable backup power solution for industrial parks, commercial buildings, factories and key facilities.

 

FAQ Section

1. Q: Does it support parallel operation of multiple Cummins generator units?

A: Yes. Using generator units of the same model with an automatic paralleling cabinet allows for load sharing, redundancy backup, and expansion to the megawatt level.

 

2. Q: Can the voltage of Cummins generators be customized?

A: The standard is 400/230V three-phase four-wire. Customization options include 480V, 600V, 690V, and medium voltage 10.5kV, but prior confirmation is required.

 

3. Q: What if starting is difficult in low-temperature environments?

A: Optional cylinder heaters, intake air preheating, or coolant heating systems can be added, ensuring reliable starting in environments from -15℃ to -30℃.

 

4. Q: What are the common fault alarms?

A: Low oil pressure, high water temperature, overspeed, overload, charging failure, fuel water content alarms, etc. The intelligent panel can display fault codes and automatically shut down the generator for protection.

 