♦ The 1100-1300KW Cummins series (including 1200KW) features a V20 electronically controlled high-pressure common rail engine with dual turbocharging and staged fuel injection technology, improving fuel economy by 10%. Specifically designed for ultra-large data centers, semiconductor fabrication plants, and rail transit traction power supply.
♦ Standard dual electronic governors and dual power control modules enable automatic switching between primary and backup systems within milliseconds. Built-in pre-lubrication and preheating systems cut cold start time by 50%, allowing the unit to reach full load within 15 seconds from standby mode.
♦ Supports paralleling up to 10 units to form a distributed power station with a total output of 13MW. Integrated synchronizing governors and reactive power sharing functions enable seamless integration into microgrid systems. Widely used in large-scale mining, emergency command centers, and national-level disaster recovery bases.
Product Description | Cummins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-1100GFC | AT-1200GFC | AT-1500GFC | AT-1600GFC | AT-1700GFC | AT-1800GFC | AT-1900GFC | AT-2000GFC | |
| KW(=0.8KVA) | 1100 | 1200 | 1500 | 1600 | 1700 | 1800 | 1900 | 2000 | |
| KVA(=1.25KW) | 1375 | 1500 | 1875 | 2000 | 2125 | 2250 | 2375 | 2500 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 215.69 | 235.29 | 294.12 | 313.73 | 333.33 | 352.94 | 372.55 | 392.16 |
| 75% Load (L/h) | 161.76 | 176.47 | 220.59 | 235.29 | 250.00 | 264.71 | 279.41 | 294.12 | |
| 50% Load (L/h) | 107.84 | 117.65 | 147.06 | 156.86 | 166.67 | 176.47 | 186.27 | 196.08 | |
| Fuel Tank Capacity (L) | 1200 | 1500 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | |
| Open Type (L*W*H) |
Demension(mm) | 5350*2100*2600 | 5350*2100*2600 | 5400*2200*2600 | 5400*2200*2600 | 5600*2200*2800 | 5600*2200*2800 | 5700*2200*2800 | 5700*2200*2800 |
| Weight(KG) | 9500 | 9600 | 9700 | 9800 | 10800 | 11000 | 11200 | 11500 | |
| Silent Type (L*W*H) |
Demension(mm) | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 |
| Weight(KG) | 10300 | 10400 | 10500 | 10600 | 11600 | 11800 | 12000 | 12300 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Leading Fuel Efficiency with Cost-Saving Performance
This 1100KW, 1200KW and 1300KW Cummins diesel generator delivers industry-leading fuel efficiency for heavy-duty power operations. Optimized engine calibration and advanced combustion technology reduce fuel consumption by approximately 3% compared with domestic equivalent diesel generator units, effectively cutting long-term operating fuel costs. Powered by a genuine Cummins core engine, this Cummins diesel generator maintains stable power output under full and partial loads, achieving an ideal balance between high performance and energy-saving operation for continuous industrial power demands.
Comprehensive Emission Certification for Global Compliance
This high-power Cummins diesel generator is fully certified to meet multiple international and domestic emission standards, including Euro 2, Euro 3, EPA, CARB and China Non-Road Stage III regulations. The standardized exhaust treatment system enables this diesel generator to operate legally in diverse regions and environmentally restricted sites. With strict emission control and eco-friendly performance, the Cummins diesel generator eliminates export and regional compliance barriers, suiting global project deployment and environmentally regulated industrial applications.
Global Service Network for Efficient After-Sales Support
Backed by a complete global service layout, this heavy-duty Cummins diesel generator is supported by Cummins’ widespread network covering more than 160 countries and 550 authorized distribution and service institutions. Relying on the global service system of Cummins, the diesel generator enjoys rapid after-sales response, on-site maintenance, spare parts supply and professional technical support worldwide. This comprehensive service guarantee minimizes equipment downtime, simplifies overseas project operation, and makes the Cummins diesel generator a trustworthy long-term power solution for large industrial bases, remote energy projects and global engineering facilities.
FAQ Section
1. Q: What speed control method do these units use? What impact does it have on power quality?
A: Electronic speed control is used, with a steady-state voltage regulation rate ≤ ±0.5% and a steady-state frequency regulation rate ≤ ±0.5%, providing fast transient response to sudden load increases. It can provide stable output for scenarios with high power quality requirements, such as data centers and precision manufacturing.
2. Q: What is the noise level of the silent unit?
A: The noise level at 7 meters for a standard open-rack unit is approximately 95-115dB; with optional soundproof enclosures (such as the ultra-quiet type offered by the Alibaba platform), the noise can be significantly reduced, making it suitable for residential areas or noise-sensitive environments.
3. Q: Does it support ATS automatic switching and parallel operation?
A: Yes. Standard automatic start function; when paired with an ATS switching cabinet, it can automatically resume load within seconds during power outages; multiple units of the same model can be connected in parallel via a parallel cabinet to achieve load sharing and capacity expansion.
4. Q: What is the maintenance cycle for high-power generator sets?
A: Routine maintenance: Change engine oil and oil filter every 250-500 hours; change diesel and air filters every 500-1000 hours; perform cooling system flushing and comprehensive inspection every 2000 hours. Refer to the operation and maintenance manual for specific cycles.
5. Q: What are the differences between the QSK series and KTA series? How to choose?
A: The KTA series uses a traditional mechanical fuel system, with a simple structure and low maintenance costs; the QSK series uses high-pressure common rail electronic fuel injection technology, resulting in lower emissions, better fuel economy, and superior transient response. The QSK series is recommended for projects with strict emission requirements or requiring remote monitoring.