♦ The 1500-2000KW Cummins series (including 1600KW and 1800KW) features four-stroke V20 or V24 diesel engines with two-stage turbocharging and sectionalized high-pressure common rail systems, achieving fuel consumption below 210g/kWh. Designed for ultra-large data centers, marine primary power, and regional-level emergency backup systems.
♦ Fully sealed protective enclosure (IP23 rating) integrates fuel heating, automatic water heating, and cam-type anti-vibration base, ensuring stable operation from -25°C to 50°C. Dual 24V starter motors and redundant lubricating oil pumps come standard, significantly improving starting success rates and continuous operation capability.
♦ Built-in industrial PLC and touchscreen monitoring station support Modbus/Profibus protocols for integration into dynamic environment monitoring systems. Supports ring-type paralleling of up to 16 units with automatic load sharing, achieving a total paralleled output of 32MW. Widely used in national-level disaster recovery centers, refining complexes, and large-scale mining sites.
Product Description | Cummins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-1100GFC | AT-1200GFC | AT-1500GFC | AT-1600GFC | AT-1700GFC | AT-1800GFC | AT-1900GFC | AT-2000GFC | |
| KW(=0.8KVA) | 1100 | 1200 | 1500 | 1600 | 1700 | 1800 | 1900 | 2000 | |
| KVA(=1.25KW) | 1375 | 1500 | 1875 | 2000 | 2125 | 2250 | 2375 | 2500 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 215.69 | 235.29 | 294.12 | 313.73 | 333.33 | 352.94 | 372.55 | 392.16 |
| 75% Load (L/h) | 161.76 | 176.47 | 220.59 | 235.29 | 250.00 | 264.71 | 279.41 | 294.12 | |
| 50% Load (L/h) | 107.84 | 117.65 | 147.06 | 156.86 | 166.67 | 176.47 | 186.27 | 196.08 | |
| Fuel Tank Capacity (L) | 1200 | 1500 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | |
| Open Type (L*W*H) |
Demension(mm) | 5350*2100*2600 | 5350*2100*2600 | 5400*2200*2600 | 5400*2200*2600 | 5600*2200*2800 | 5600*2200*2800 | 5700*2200*2800 | 5700*2200*2800 |
| Weight(KG) | 9500 | 9600 | 9700 | 9800 | 10800 | 11000 | 11200 | 11500 | |
| Silent Type (L*W*H) |
Demension(mm) | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 |
| Weight(KG) | 10300 | 10400 | 10500 | 10600 | 11600 | 11800 | 12000 | 12300 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Micro-Grid Hybrid Technology for Optimized Energy Operation
This 1500KW, 1600KW, 1800KW and 2000KW Cummins diesel generator is equipped with advanced micro-grid hybrid technology, realizing intelligent linkage between energy storage and power generation units. As a high-capacity industrial diesel generator, it effectively stabilizes power fluctuation and balances grid load changes. The optimized hybrid energy solution cuts down overall project initial investment and improves energy utilization efficiency. Driven by original Cummins engine core, this Cummins diesel generator perfectly adapts to new energy hybrid systems, providing stable, economical and intelligent power guarantee for large industrial parks, off-grid bases and comprehensive energy projects.
Custom Silent Design for Noise-Sensitive Scenarios
The enclosed silent type Cummins diesel generator is professionally optimized with sound insulation, shock absorption and noise reduction structures, controlling operating sound within 70-80dB(A). Compared with conventional high-power diesel generator units, it delivers outstanding quiet performance and effectively reduces environmental noise pollution. With mature mute configuration and stable power output of Cummins power system, this unit is highly suitable for hospitals, residential communities, urban commercial zones and other noise-sensitive areas, meeting strict daily noise control and environmental protection requirements.
Excellent High-Altitude Adaptability for Harsh Plateau Environments
Specially calibrated with customized turbocharger parameters, this heavy-duty Cummins diesel generator boasts powerful plateau adaptability. It can maintain stable power output and normal continuous operation at an altitude up to 3000 meters, avoiding power attenuation and abnormal operation caused by thin air. Reinforced high-altitude matching design enables this large-scale diesel generator to cope with complex plateau, mountain and remote high-altitude working conditions. Relying on the strong environmental resistance of Cummins industrial power equipment, it ensures reliable and uninterrupted power supply in harsh and high-altitude regions.
FAQ Section
1. Q: What are the characteristics of the Cummins PT fuel system? How to maintain it on high-power generator sets?
A: The PT system (Pressure-Time) is a Cummins patented technology that controls fuel supply through pressure and time. For high-power generator sets, please note: keep the fuel clean, replace the filter regularly, and prevent the fuel temperature from becoming too high (recommended to be below 45℃), otherwise it may cause thermal expansion and jamming of actuator components.
2. Q: What are the emission standards for Cummins generator sets?
A: New models (such as the QSK series) use high-pressure common rail + SCR aftertreatment, which can meet the latest emission standards such as China's non-road China IV, EPA Tier 4 Final, and EU Stage V. The requirements of the target market need to be confirmed before export.
3. Q: What are the protection functions of the generator set?
A: Standard configuration includes multiple protections such as low oil pressure, high water temperature, overspeed, underspeed, overload, and start-up failure. The control system monitors and displays various parameters in real time, automatically shutting down and alarming in case of abnormalities.
4. Q: What precautions should be taken when installing a high-power generator set on-site?
A: ① The foundation must be reinforced concrete with a pressure resistance exceeding 173 kPa; ② The air inlet should be located at the generator end, and the exhaust outlet at the water tank end; ③ Ensure sufficient fresh air volume; ④ Vibration dampers are recommended; ⑤ The generator room must be equipped with a fire protection and smoke extraction system.
5. Q: Does Cummins provide remote monitoring functionality?
A: Yes. The intelligent control panel has a communication interface (RS232/RS485), and an optional IoT module can be installed, allowing remote viewing of generator operating data and historical alarms via mobile phone or computer, enabling unattended management.
6. Q: What is the warranty period for Cummins generator sets?
A: The standard warranty period is 2 years or 2000 operating hours (whichever comes first). Extended warranties are available for some export models; please confirm the specific terms with the supplier.