♦ This 400-520KW Cummins series (including 460KW, 500KW) features original Cummins heavy-duty engines, equipped with large-capacity radiators and dual centrifugal air filters to withstand high-dust and high-temperature environments. Ideal for critical power protection in large mines, airports, data centers, and similar applications.
♦ Electronic high-pressure common rail fuel system delivers low fuel consumption of just 198g/kWh, with maintenance intervals extended to 500 hours. All cast-iron construction and reinforced crankshaft design provide an overhaul life exceeding 30,000 hours, significantly reducing total lifecycle costs.
♦ Supports direct paralleling of up to 8 identical units, achieving a total power output of over 4000KW. Equipped with synchronization controllers and load sharing modules for automatic paralleling and de-paralleling. Suitable for industrial parks, large commercial complexes, and regional grid peak-load backup.
Product Description | Cummins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-160GFC | AT-180GFC | AT-200GFC | AT-250GFC | AT-300GFC | AT-320GFC | AT-360GFC | AT-400GFC | |
| Genset Power | KW(=0.8KVA) | 160 | 180 | 200 | 250 | 300 | 320 | 360 | 400 |
| KVA(=1.25KW) | 200 | 225 | 250 | 312.5 | 375 | 400 | 450 | 500 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 31.37 | 35.29 | 39.22 | 49.02 | 58.82 | 62.75 | 70.59 | 78.43 |
| 75% Load (L/h) | 23.53 | 26.47 | 29.41 | 36.76 | 44.12 | 47.06 | 52.94 | 58.82 | |
| 50% Load (L/h) | 15.69 | 17.65 | 19.61 | 24.51 | 29.41 | 31.37 | 35.29 | 39.22 | |
| Fuel Tank Capacity (L) | 200 | 200 | 280 | 300 | 500 | 500 | 600 | 600 | |
| Open Type (L*W*H) |
Demension(mm) | 2500*1050*1700 | 2500*1050*1700 | 2600*1050*1700 | 2700*1150*1700 | 2750*1150*1700 | 2750*1150*1700 | 3200*1370*1900 | 3200*1370*1900 |
| Weight(KG) | 1750 | 1900 | 2000 | 2100 | 2300 | 2800 | 3150 | 3200 | |
| Silent Type (L*W*H) |
Demension(mm) | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 |
| Weight(KG) | 1750 | 1900 | 2000 | 2100 | 2300 | 2800 | 3150 | 3200 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Centennial Brand Credibility with Global Leading Strength
This 400KW, 460KW, 500KW and 520KW Cummins diesel generator is backed by the time-honored heritage of Cummins, founded in 1919. As a global leader in power equipment manufacturing, Cummins boasts profound technical accumulation and worldwide service networks, delivering high credibility and reliable guarantees for every unit. This industrial-grade diesel generator inherits consistent premium manufacturing standards, winning high customer recognition and long-term market trust. The mature and proven brand strength makes this Cummins diesel generator the preferred stable power solution for large industrial facilities, engineering projects and critical backup power scenarios.
Patented PT Fuel System for Stable & Efficient Operation
Equipped with the exclusive patented PT fuel system, this high-power Cummins diesel generator adopts low-pressure oil supply combined with high-pressure injection technology to realize full and uniform fuel combustion. The optimized fuel delivery structure effectively reduces overall failure rates and improves operational stability and fuel economy. With core technological advantages of Cummins engine, the diesel generator maintains efficient output under long-term heavy-load operation, lowering daily breakdown risks and simplifying routine maintenance, achieving high efficiency and low malfunction for long-duration continuous work.
Holset Exhaust Turbocharger for Strong Dynamic Performance
This premium Cummins diesel generator is fitted with original Holset exhaust turbocharger, which greatly enhances air intake efficiency and ensures sufficient oxygen supply for combustion. It delivers sensitive power response and strong instantaneous load capacity, adapting to complex load changes and harsh working conditions. The perfect matching of Holset turbocharging technology and Cummins core power further upgrades the overall performance of the diesel generator, featuring stronger power reserve, faster dynamic feedback and excellent operational stability, meeting the high-intensity power demand of large-scale industrial production and off-grid power supply.
FAQ Section
1. Q: What are the fuel requirements for Cummins generators?
A: We recommend using standard 0# or -10# light diesel oil. High-power electronically controlled models have higher requirements for fuel cleanliness; we recommend using an oil-water separator.
2. Q: What preparations are needed before starting a new generator set for the first time?
A: Add engine oil, coolant, and diesel fuel; check the battery voltage and connections; perform a no-load test run for 5-10 minutes to confirm stable voltage and frequency and no leaks.
3. Q: What is the maintenance cycle?
A: Regularly change the engine oil and oil filter every 250-500 hours; change the diesel filter and air filter every 500-1000 hours; for high-power electronically controlled models, we recommend using original factory filters.
4. Q: Does it support parallel operation of multiple Cummins generator units?
A: Yes. Using generator units of the same model with an automatic paralleling cabinet allows for load sharing, redundancy backup, and expansion to the megawatt level.