Deutz
Deutz
200KW DEUTZ Diesel Generator 220KW 240KW 280KW
200KW DEUTZ Diesel Generator 220KW 240KW 280KW

200KW DEUTZ Diesel Generator 220KW 240KW 280KW

Product Introduction

♦ Modular Cooling System
The 200-280KW DEUTZ diesel generator set (including 220KW, 240KW) features an independent dual-fan cooling package, capable of full-load operation without overheating at ambient temperatures of 50°C. Suitable for oil drilling, tunnel boring, and black start backup for thermal power plants.

 

♦ Dual-Start Redundancy Configuration
Standard dual 24V high-capacity starter motors and dual battery chargers, with automatic switch to the backup system if the primary start fails. Built-in pre-lubrication electric oil pump automatically builds oil pressure before starting, reducing cold start wear by 50%.

 

♦ Unattended Remote Management
Equipped with a 4G IoT controller supporting remote start/stop, parameter adjustment, and fault diagnosis via a mobile app. Data is automatically backed up to the cloud, with monthly operation reports available. Widely used in data centers, communication hubs, and large-scale farms.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Deutz-Diesel Generator  Technical Parameters
Genset Model AT-160GFD AT-180GFD AT-200GFD AT-250GFD AT-300GFD AT-320GFD AT-360GFD AT-400GFD
Genset Power KW(=0.8KVA) 160 180 200 250 300 320 360 400
KVA(=1.25KW) 200 225 250 312.5 375 400 450 500
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 31.37  35.29  39.22  49.02  58.82  62.75  70.59  78.43 
75% Load (L/h) 23.53  26.47  29.41  36.76  44.12  47.06  52.94  58.82 
50% Load (L/h) 15.69  17.65  19.61  24.51  29.41  31.37  35.29  39.22 
Fuel Tank Capacity (L) 200 200 280 300 500 500 600 600
Open Type
(L*W*H)
Demension(mm) 2500*1050*1700 2500*1050*1700 2600*1050*1700 2700*1150*1700 2750*1150*1700 2750*1150*1700 3200*1370*1900 3200*1370*1900
Weight(KG) 1750 1900 2000 2100 2300 2800 3150 3200
Silent Type
(L*W*H)
Demension(mm) 3000*1100*1700 3000*1100*1700 3000*1100*1700 3000*1100*1700 3000*1100*1700 3000*1100*1700 3000*1100*1700 3000*1100*1700
Weight(KG) 1750 1900 2000 2100 2300 2800 3150 3200
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material Cast iron, stainless steel, galvanized...

 

Heavy-Duty DEUTZ Power Solution for Large Industrial Scenarios
Our 200KW, 220KW, 240KW and 280KW DEUTZ Diesel Generator adopts authentic DEUTZ core power, serving as a high-load industrial-grade diesel generator for factories, industrial parks and large-scale backup power scenarios. The 250KW and 280KW models are compatible with ATS automatic switching function, achieving automatic start, stop and power switching when the mains power fails, realizing unattended intelligent power supply and greatly improving power supply stability.

 

Diversified Cabinet Type Design for Flexible Deployment
This high-power DEUTZ Diesel Generator provides silent type complete cabinet delivery as standard, with excellent sound insulation and noise reduction performance, which can adapt to noise-restricted working areas. Meanwhile, the rainproof type unit is optional, featuring excellent outdoor weather resistance, allowing rapid on-site deployment and stable operation in open-air, outdoor and complex environmental sites. Multiple cabinet styles fully meet the differentiated layout needs of different customers.

 

Flexible Cylinder Configuration & Stable Overall Performance
To match diverse load and working condition demands, this diesel generator supports two kinds of cylinder arrangement options for free selection. With mature DEUTZ engine technology, reasonable structural layout and strong power reserve, the whole machine runs stably under long-term heavy load. Combining intelligent ATS configuration, dual-style cabinet design and flexible cylinder arrangement, the 200–280KW DEUTZ Diesel Generator is a reliable, adaptable and high-cost performance large power supply equipment for industrial production and emergency power backup.

 

FAQ Section

1. Q: What is the difference between a prime power generator and a standby generator? A: The constant-load generator is designed for continuous operation and can be used as the main power source; the standby generator serves as a backup power source and only operates during power outages.

 

2. Q: What kind of installation foundation is required for a Deutz generator?

A: A reinforced concrete base needs to be poured on the floor, with a pressure test exceeding 173 kPa; the base should be at least 150 mm above the floor, extending at least 150 mm along each side of the generator chassis, and pre-embedded with "J" or "L" type anchor bolts.

 

3. Q: What are the requirements for the generator room design?

A: The generator set should preferably be arranged horizontally; the generator room should have sufficient fresh air inlets, with the air inlets located on the generator side and the exhaust outlets located on the water tank side; comprehensive noise reduction measures for the generator set and sound insulation of the generator room should be adopted.

 

4. Q: How is vibration controlled in a Deutz generator set?

A: Vibration dampers must be installed between the engine and the fuel tank. Some units (such as the JG series) adopt a built-in multi-stage vibration damping system design, which can effectively eliminate vibration and protect the control system and electrical components.

Please fill in the following information and submit it before downloading the file