Kubota
Kubota
20KW Kubota Diesel Generator 30KW 40KW 50KW
20KW Kubota Diesel Generator 30KW 40KW 50KW

20KW Kubota Diesel Generator 30KW 40KW 50KW

Product Introduction

♦ The 20-50KW Kubota diesel generator set (including 30KW, 40KW) features an original Kubota four-stroke water-cooled engine with low-speed, high-torque output and fuel consumption as low as 210g/kWh. Suitable for small processing plants, supermarkets, farms, and telecom base stations.


♦ Standard soundproof enclosure keeps noise levels within 68 dB at 1 meter, featuring a high-efficiency muffler and acoustic insulation. Meets Euro V emission standards, allowing long-term operation in residential areas and regions with strict environmental regulations while minimizing noise and exhaust impact.


♦ Digital control panel displays real-time voltage, frequency, oil pressure, coolant temperature, and runtime. Features automatic shutdown protection for low oil pressure, overload, and high temperature. Optional ATS automatic transfer switch enables unattended automatic power supply.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Kubota-Diesel Generator  Technical Parameters
Genset Model AT-16GFK AT-20GFK AT-25GFK AT-30GFK AT-40GFK AT-50GFK
Genset Power KW(=0.8KVA) 16 20 25 30 40 50
KVA(=1.25KW) 20 25 31.25 37.5 50 62.5
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 3.14  3.92  4.90  5.88  7.84  9.80 
75% Load (L/h) 2.35  2.94  3.68  4.41  5.88  7.35 
50% Load (L/h) 1.57  1.96  2.45  2.94  3.92  4.90 
Fuel Tank Capacity (L) 100 100 100 100 100 100
Open Type
(L*W*H)
Demension(mm) 1700*800*1250 1700*800*1250 1800*800*1300 1800*800*1300 1850*800*1300 1850*800*1300
Weight(KG) 700 750 750 800 800 820
Silent Type
(L*W*H)
Demension(mm) 2200*1000*1400 2200*1000*1400 2200*1000*1400 2200*1000*1400 2200*1000*1400 2200*1000*1400
Weight(KG) 1100 1150 1150 1200 1200 1220
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material

Cast iron, stainless steel, galvanized...

 

 

Compatibility with HVO Renewable Diesel
This 20KW, 30KW, 40KW and 50KW Kubota diesel generator is fully compatible with HVO renewable diesel, enabling the use of eco-friendly alternative fuels to meet global sustainable development goals. By adopting clean renewable fuel, this advanced diesel generator achieves greatly reduced carbon emissions and eco-friendlier daily operation. Powered by an authentic Kubota engine, the Kubota diesel generator maintains stable power output and reliable running performance while supporting green energy applications, perfectly fitting low-carbon projects, environmental protection zones and international sustainable power supply demands.

 

Compact and Lightweight Body Structure
Featuring optimized compact and lightweight design, this high-performance Kubota diesel generator boasts smaller overall size and lighter weight than conventional same-power diesel generator products. The streamlined structural layout greatly simplifies logistics transportation, on-site handling and installation deployment. With space-saving advantages and flexible layout characteristics, the original Kubota power unit adapts to limited installation spaces, mobile working platforms and scattered layout scenarios. It brings higher convenience and flexibility for equipment arrangement, transportation transfer and daily site layout.

 

Automatic Shutdown Protection for Operational Safety
Equipped with comprehensive intelligent monitoring systems, this industrial-grade Kubota diesel generator provides complete abnormal protection functions. It will trigger automatic shutdown and alarm prompts in case of low oil pressure, high water temperature, overspeed and other faulty conditions, effectively avoiding core component damage caused by abnormal operating parameters. This all-round safety mechanism strengthens the operation stability and prolongs the service life of the diesel generator. With humanized intelligent protection and reliable Kubota core quality, this Kubota diesel generator realizes unattended safe operation and reduces equipment failure risks in long-term working conditions.

 

FAQ Section

1. Q: How fuel-efficient is the Kubota generator?

A: Taking the SQ3300B (30kVA) as an example, it has a full-load range of approximately 24 hours, a fuel tank capacity of 142 liters, and excellent fuel economy. Kubota engines generally employ TVCS combustion technology and high-pressure injection systems, significantly reducing fuel consumption while ensuring power output.

 

2. Q: In what special scenarios can Kubota generators be used?

A: Kubota generators have a wide range of applications. For example, its GL11000-USA model has been successfully used in NASCAR race car pit stops to power large displays and complex data systems. In addition, Kubota engines are widely used in LED lighthouses, yachts, RVs, communication base stations, etc.

 

3. Q: What are the requirements for fuel and engine oil for Kubota generators?

A: Clean, national standard diesel fuel is recommended. The appropriate grade of engine oil should be selected according to the operation manual. It should be noted that Kubota engines have been approved to use HVO renewable diesel fuel, meeting sustainable development requirements. After long-term storage, the fuel condition should be checked before starting to avoid water content in the fuel affecting performance.

 

4. Q: What should I pay attention to during daily inspections of a Kubota generator?

A: Before starting each day, check the following: engine oil level (should be within the marked cross lines), coolant level (between FULL and ADD in the auxiliary water tank), and fan belt condition (for cracks or looseness). Also check for oil/water/fuel leaks and ensure the air intake is not blocked. Additionally, checking the battery terminals for corrosion is also important.

 

5. Q: What are the advantages and disadvantages of Kubota generators compared to Cummins in the low-power segment?

A: The advantages of Kubota are higher product precision in the low-power segment (<50kVA), better maintenance convenience (single-sided maintenance, automatic venting), and excellent noise control. Some models have an oil change interval of up to 1000 hours, significantly reducing the total cost of ownership. The disadvantages are fewer high-power models and slightly lower brand recognition in large industrial projects compared to Cummins.

Please fill in the following information and submit it before downloading the file