♦ Large-Displacement Core Power:
The 800-1000KW Mitsubishi diesel generator set (including 900KW) features an original Mitsubishi V16/V18 engine with four-valve and turbocharged intercooling technology. With large displacement and ample torque reserve, it can handle instantaneous load surges. This Mitsubishi diesel generator is an ideal choice for heavy industry, large mining areas, and regional power grid backup.
♦ Efficient Heavy-Duty Cooling:
Equipped with a standard independent large-capacity radiator and temperature-controlled intelligent fan, this diesel generator maintains continuous full-load operation without power derating even in a 45°C high-temperature environment. The generator features Class H insulation and a brushless excitation system, with a stator specially treated for moisture resistance, making it suitable for high-humidity and high-heat environments such as coastal power plants and tunnel engineering.
♦ Power Station Grade Paralleling Capability:
With a built-advanced paralleling control module, this Mitsubishi diesel generator supports direct paralleling of up to 16 units to form a megawatt-level power station, achieving automatic load sharing. This diesel generator supports remote monitoring and unattended operation, and is widely used in emergency backup power systems for supercomputing centers, large semiconductor fabs, and international airports.
Product Description | Mitsubishi -Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-500GFM | AT-550GFM | AT-600GFM | AT-650GFM | AT-700GFM | AT-800GFM | AT-900GFM | AT-1000GFM | |
| Genset Power | KW(=0.8KVA) | 500 | 550 | 600 | 650 | 700 | 800 | 900 | 1000 |
| KVA(=1.25KW) | 625 | 687.5 | 750 | 812.5 | 875 | 1000 | 1125 | 1250 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 98.04 | 107.84 | 117.65 | 127.45 | 137.25 | 156.86 | 176.47 | 196.08 |
| 75% Load (L/h) | 73.53 | 80.88 | 88.24 | 95.59 | 102.94 | 117.65 | 132.35 | 147.06 | |
| 50% Load (L/h) | 49.02 | 53.92 | 58.82 | 63.73 | 68.63 | 78.43 | 88.24 | 98.04 | |
| Fuel Tank Capacity (L) | 600 | 600 | 800 | 800 | 800 | 1000 | 1000 | 1200 | |
| Open Type (L*W*H) |
Demension(mm) | 3500*1400*2100 | 3600*1550*2200 | 4300*1800*2500 | 4300*1800*2500 | 4350*1800*2500 | 4400*1800*2500 | 4450*1800*2500 | 4450*1800*2500 |
| Weight(KG) | 4200 | 4500 | 7100 | 7300 | 7600 | 7800 | 7900 | 8200 | |
| Silent Type (L*W*H) |
Demension(mm) | 4000*1600*2100 | 4000*1600*2100 | 4600*2000*2300 | 4600*2000*2300 | 4600*2200*2300 | 4600*2200*2300 | 5200*2300*2500 | 5200*2300*2500 |
| Weight(KG) | 4750 | 5050 | 7650 | 7850 | 8150 | 8350 | 8450 | 8750 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Outstanding Fuel Economy
The Mitsubishi diesel generator in 800KW, 900KW and 1000KW power grades delivers remarkable fuel-saving performance. Its minimum fuel consumption rate reaches 198-215g/kW·h, taking a leading position in economy among the same power segment. As a high-efficiency diesel generator, it effectively cuts down long-term fuel consumption and operational expenses. Relying on optimized combustion technology of Mitsubishi, the unit maintains efficient operation all year round and brings obvious cost advantages for long-duration continuous power supply projects.
G3 Transient Performance Certified
This Mitsubishi diesel generator fully complies with ISO 8528 G3 international standard. It realizes fast start-up within 10 seconds and one-step 100% full load capacity. Such excellent transient response enables this diesel generator to cope with sudden power demand changes steadily. With reliable dynamic performance, Mitsubishi power units can stably support critical loads, avoid power fluctuation risks, and ensure safe and uninterrupted power supply for core industrial and important infrastructure facilities.
Tier III / IV Certification for Data Centers
The high-power Mitsubishi diesel generator has obtained professional Tier III and Tier IV certification issued by the Uptime Institute. It is recognized as the preferred power equipment for world-class large data centers. This premium diesel generator features ultra-high stability, low failure rate and strict power supply standards. Backed by Mitsubishi sophisticated manufacturing technology, it perfectly meets the stringent redundancy and continuous operation requirements of high-standard data center construction worldwide.
-12℃ Cold Start Without Auxiliary Heating
Designed with excellent low-temperature adaptability, the Mitsubishi diesel generator can start normally at -12℃ without any auxiliary heating device. It breaks the limitation of harsh cold climates and greatly expands the application scope of this diesel generator. With professional cold resistance calibration and core component optimization, Mitsubishi high-power units can operate stably all year round in northern cold regions, remote mining areas and outdoor engineering sites with extreme temperature conditions.
FAQ Section
1. Q: What are the manufacturing standards for Mitsubishi generator sets?
A: Mitsubishi generator sets comply with ISO8528, IEC international standards, JIS Japanese Industrial Standards, and GB2820 Chinese Standards. Electrical performance complies with BS EN 60950 low-voltage standards and BS EN50081-2 and 50082-2 EMC electromagnetic compatibility standards.
2. Q: What are the standard core components of a Mitsubishi generator set?
A: Standard configuration includes: a Mitsubishi original four-stroke water-cooled diesel engine, a Deep Sea intelligent controller, a 40°C ambient temperature radiator, a steel structure vibration-damping base with a chassis fuel tank, a generator output circuit breaker, battery connection cables, a muffler, etc.
3. Q: What are the electrical performance parameters of a Mitsubishi generator set?
A: Standard configuration: rated voltage 400V/230V, three-phase four-wire wiring, rated frequency 50Hz, power factor 0.8 (lagging). It can also meet user requirements for 60Hz and other internationally accepted standards.
4. Q: How is the fuel economy of a Mitsubishi generator?
A: Fuel economy is outstanding. Mitsubishi engines boast industry-leading fuel efficiency in their power range. Taking the S6A3-PTA-S model as an example, its efficient fuel injection system and turbocharging technology result in excellent fuel economy under full load.