Mitsubishi
Mitsubishi
800KW Mitsubishi Diesel Generator 900KW 1000KW
800KW Mitsubishi Diesel Generator 900KW 1000KW

800KW Mitsubishi Diesel Generator 900KW 1000KW

Product Introduction

Large-Displacement Core Power: 
The 800-1000KW Mitsubishi diesel generator set (including 900KW) features an original Mitsubishi V16/V18 engine with four-valve and turbocharged intercooling technology. With large displacement and ample torque reserve, it can handle instantaneous load surges. This Mitsubishi diesel generator is an ideal choice for heavy industry, large mining areas, and regional power grid backup.

Efficient Heavy-Duty Cooling: 
Equipped with a standard independent large-capacity radiator and temperature-controlled intelligent fan, this diesel generator maintains continuous full-load operation without power derating even in a 45°C high-temperature environment. The generator features Class H insulation and a brushless excitation system, with a stator specially treated for moisture resistance, making it suitable for high-humidity and high-heat environments such as coastal power plants and tunnel engineering.

Power Station Grade Paralleling Capability:
 With a built-advanced paralleling control module, this Mitsubishi diesel generator supports direct paralleling of up to 16 units to form a megawatt-level power station, achieving automatic load sharing. This diesel generator supports remote monitoring and unattended operation, and is widely used in emergency backup power systems for supercomputing centers, large semiconductor fabs, and international airports.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Mitsubishi -Diesel Generator  Technical Parameters
Genset Model AT-500GFM AT-550GFM AT-600GFM AT-650GFM AT-700GFM AT-800GFM AT-900GFM AT-1000GFM
Genset Power KW(=0.8KVA) 500 550 600 650 700 800 900 1000
KVA(=1.25KW) 625 687.5 750 812.5 875 1000 1125 1250
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 98.04  107.84  117.65  127.45  137.25  156.86  176.47  196.08 
75% Load (L/h) 73.53  80.88  88.24  95.59  102.94  117.65  132.35  147.06 
50% Load (L/h) 49.02  53.92  58.82  63.73  68.63  78.43  88.24  98.04 
Fuel Tank Capacity (L) 600 600 800 800 800 1000 1000 1200
Open Type
(L*W*H)
Demension(mm) 3500*1400*2100 3600*1550*2200 4300*1800*2500 4300*1800*2500 4350*1800*2500 4400*1800*2500 4450*1800*2500 4450*1800*2500
Weight(KG) 4200 4500 7100 7300 7600 7800 7900 8200
Silent Type
(L*W*H)
Demension(mm) 4000*1600*2100 4000*1600*2100 4600*2000*2300 4600*2000*2300 4600*2200*2300 4600*2200*2300 5200*2300*2500 5200*2300*2500
Weight(KG) 4750 5050 7650 7850 8150 8350 8450 8750
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material Cast iron, stainless steel, galvanized...

 

Outstanding Fuel Economy
The Mitsubishi diesel generator in 800KW, 900KW and 1000KW power grades delivers remarkable fuel-saving performance. Its minimum fuel consumption rate reaches 198-215g/kW·h, taking a leading position in economy among the same power segment. As a high-efficiency diesel generator, it effectively cuts down long-term fuel consumption and operational expenses. Relying on optimized combustion technology of Mitsubishi, the unit maintains efficient operation all year round and brings obvious cost advantages for long-duration continuous power supply projects.

 

G3 Transient Performance Certified
This Mitsubishi diesel generator fully complies with ISO 8528 G3 international standard. It realizes fast start-up within 10 seconds and one-step 100% full load capacity. Such excellent transient response enables this diesel generator to cope with sudden power demand changes steadily. With reliable dynamic performance, Mitsubishi power units can stably support critical loads, avoid power fluctuation risks, and ensure safe and uninterrupted power supply for core industrial and important infrastructure facilities.

 

Tier III / IV Certification for Data Centers
The high-power Mitsubishi diesel generator has obtained professional Tier III and Tier IV certification issued by the Uptime Institute. It is recognized as the preferred power equipment for world-class large data centers. This premium diesel generator features ultra-high stability, low failure rate and strict power supply standards. Backed by Mitsubishi sophisticated manufacturing technology, it perfectly meets the stringent redundancy and continuous operation requirements of high-standard data center construction worldwide.

 

-12℃ Cold Start Without Auxiliary Heating
Designed with excellent low-temperature adaptability, the Mitsubishi diesel generator can start normally at -12℃ without any auxiliary heating device. It breaks the limitation of harsh cold climates and greatly expands the application scope of this diesel generator. With professional cold resistance calibration and core component optimization, Mitsubishi high-power units can operate stably all year round in northern cold regions, remote mining areas and outdoor engineering sites with extreme temperature conditions.

 

FAQ Section

1. Q: What are the manufacturing standards for Mitsubishi generator sets?

A: Mitsubishi generator sets comply with ISO8528, IEC international standards, JIS Japanese Industrial Standards, and GB2820 Chinese Standards. Electrical performance complies with BS EN 60950 low-voltage standards and BS EN50081-2 and 50082-2 EMC electromagnetic compatibility standards.

 

2. Q: What are the standard core components of a Mitsubishi generator set?

A: Standard configuration includes: a Mitsubishi original four-stroke water-cooled diesel engine, a Deep Sea intelligent controller, a 40°C ambient temperature radiator, a steel structure vibration-damping base with a chassis fuel tank, a generator output circuit breaker, battery connection cables, a muffler, etc.

 

3. Q: What are the electrical performance parameters of a Mitsubishi generator set?

A: Standard configuration: rated voltage 400V/230V, three-phase four-wire wiring, rated frequency 50Hz, power factor 0.8 (lagging). It can also meet user requirements for 60Hz and other internationally accepted standards.

 

4. Q: How is the fuel economy of a Mitsubishi generator?

A: Fuel economy is outstanding. Mitsubishi engines boast industry-leading fuel efficiency in their power range. Taking the S6A3-PTA-S model as an example, its efficient fuel injection system and turbocharging technology result in excellent fuel economy under full load.

 

Please fill in the following information and submit it before downloading the file