♦ We offer a full range of ultra-high power Perkins diesel generator models, including 1100KW, 1200KW and 1300KW, to meet the differentiated ultra-high load power demands of large-scale industrial and commercial users.
♦ Powered by the original Perkins engine, this diesel generator integrates three core advantages: excellent water-to-air intercooling heat dissipation, intelligent remote monitoring and fault diagnosis, and low-base shock absorption design, delivering outstanding overall performance and strong operational reliability.
♦ This perkins diesel generator maintains excellent temperature rise control under high-load working conditions, ensuring stable continuous operation; the IoT-enabled remote monitoring function realizes unattended operation and maintenance, saving labor costs; the low-base design simplifies installation and reduces civil engineering investment, further enhancing its cost-effectiveness.
Product Description | Perkins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-1100GFP | AT-1200GFP | AT-1500GFP | AT-1600GFP | AT-1700GFP | AT-1800GFP | AT-1900GFP | AT-2000GFP | |
| KW(=0.8KVA) | 1100 | 1200 | 1500 | 1600 | 1700 | 1800 | 1900 | 2000 | |
| KVA(=1.25KW) | 1375 | 1500 | 1875 | 2000 | 2125 | 2250 | 2375 | 2500 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 215.69 | 235.29 | 294.12 | 313.73 | 333.33 | 352.94 | 372.55 | 392.16 |
| 75% Load (L/h) | 161.76 | 176.47 | 220.59 | 235.29 | 250.00 | 264.71 | 279.41 | 294.12 | |
| 50% Load (L/h) | 107.84 | 117.65 | 147.06 | 156.86 | 166.67 | 176.47 | 186.27 | 196.08 | |
| Fuel Tank Capacity (L) | 1200 | 1500 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | |
| Open Type (L*W*H) |
Demension(mm) | 5350*2100*2600 | 5350*2100*2600 | 5400*2200*2600 | 5400*2200*2600 | 5600*2200*2800 | 5600*2200*2800 | 5700*2200*2800 | 5700*2200*2800 |
| Weight(KG) | 9500 | 9600 | 9700 | 9800 | 10800 | 11000 | 11200 | 11500 | |
| Silent Type (L*W*H) |
Demension(mm) | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 | 6000*2300*2600 |
| Weight(KG) | 10300 | 10400 | 10500 | 10600 | 11600 | 11800 | 12000 | 12300 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
High-Efficiency Heat Dissipation and Intelligent Operation for Ultra-High Power Demands
Our 1100KW, 1200KW, 1300KW Perkins diesel generator is specially engineered to tackle the rigorous power needs of large-scale industrial and commercial scenarios, delivering unmatched reliability and adaptability. As a high-performance diesel generator, it is powered by the authentic Perkins engine, integrating advanced water-to-air intercooling heat dissipation technology that stands out in heat dissipation capacity. Even under long-term high-load working conditions, this Perkins diesel generator achieves excellent temperature rise control, effectively preventing overheating failures and ensuring more stable and reliable continuous operation, which is crucial for critical industrial processes that require uninterrupted power supply.
Advanced Intelligent Configuration and Optimized Structural Design
Beyond superior heat dissipation, this diesel generator is equipped with intelligent remote monitoring and fault diagnosis functions, featuring a reserved IoT interface that supports real-time data monitoring, operation management and automatic fault early warning. This intelligent design allows for unattended operation and maintenance of the Perkins diesel generator, greatly reducing manual intervention, saving labor costs, and making long-term on-site operation more worry-free and secure. In terms of structural optimization, the Perkins diesel generator adopts a low-base and integrated shock absorption design, which eliminates the need for complex foundation construction during installation. This not only simplifies the on-site deployment process but also significantly reduces civil engineering costs, enhancing the flexibility of this high-power diesel generator in various complex installation environments.
Reliable Power Support for Large-Scale Industrial Applications
The 1100KW, 1200KW, 1300KW Perkins diesel generator combines the robust performance of Perkins engines with optimized technical configurations, balancing ultra-high power output, stable operation and cost-saving advantages. It is widely applicable to large industrial parks, mining operations, chemical plants, large data centers, municipal engineering projects and remote field construction sites. Whether used as the main power supply for long-term full-load production or as an emergency backup power supply to cope with grid interruptions, this diesel generator can respond efficiently, providing continuous, stable and cost-effective power guarantee. Its compliance with international industry standards and excellent environmental adaptability also ensure that it can meet the stringent requirements of various large-scale industrial scenarios, becoming a reliable high-power energy solution for enterprises.
FAQ Section
1. Q: How do I choose between Reserve Power (PRP) and Common Operating Power (COP)?
A: Standby power is suitable for emergency scenarios with annual operating hours <200 hours; mains power is suitable for long-term continuous power supply (such as main power supply or construction site).
2. Q: What are the fuel requirements for Perkins generators?
A: It is recommended to use clean 0# or -10# light diesel oil (national standard). High-power models can be equipped with a heavy oil system to improve fuel flexibility.
3. Q: What preparations are needed before the first start-up?
A: Add engine oil, coolant, and diesel oil; check battery voltage and wiring; test the engine under no-load for 5-10 minutes to confirm voltage and frequency stability.
4. Q: What is the maintenance cycle?
A: The standard is to change the engine oil and oil filter every 250-500 hours; change the diesel filter and air filter every 1000 hours; high-power models have longer maintenance intervals.