Perkins
Perkins
400KW Perkins Diesel Generator 460KW 500KW 520KW
400KW Perkins Diesel Generator 460KW 500KW 520KW

400KW Perkins Diesel Generator 460KW 500KW 520KW

Product Introduction

♦ The 400KW, 460KW, 500KW and 520KW Perkins diesel generator series is designed for large industrial and commercial users with high-standard power demands.

 

♦ Powered by genuine Perkins engines and matched with high-performance alternators, this diesel generator series delivers stable and strong power output for large factories, data centers, infrastructure facilities and important public sites. 

 

♦ With high reliability and strong adaptability, it has become the preferred high-power power solution for modern power systems.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Perkins-Diesel Generator  Technical Parameters
Genset Model AT-500GFP AT-550GFP AT-600GFP AT-650GFP AT-700GFP AT-800GFP AT-900GFP AT-1000GFP
Genset Power KW(=0.8KVA) 500 550 600 650 700 800 900 1000
KVA(=1.25KW) 625 687.5 750 812.5 875 1000 1125 1250
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 98.04  107.84  117.65  127.45  137.25  156.86  176.47  196.08 
75% Load (L/h) 73.53  80.88  88.24  95.59  102.94  117.65  132.35  147.06 
50% Load (L/h) 49.02  53.92  58.82  63.73  68.63  78.43  88.24  98.04 
Fuel Tank Capacity (L) 600 600 800 800 800 1000 1000 1200
Open Type
(L*W*H)
Demension(mm) 3500*1400*2100 3600*1550*2200 4300*1800*2500 4300*1800*2500 4350*1800*2500 4400*1800*2500 4450*1800*2500 4450*1800*2500
Weight(KG) 4200 4500 7100 7300 7600 7800 7900 8200
Silent Type
(L*W*H)
Demension(mm) 4000*1600*2100 4000*1600*2100 4600*2000*2300 4600*2000*2300 4600*2200*2300 4600*2200*2300 5200*2300*2500 5200*2300*2500
Weight(KG) 4750 5050 7650 7850 8150 8350 8450 8750
  Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
  Connector Plug

Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....

Custom Made Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
  Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
  Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
  Material Cast iron, stainless steel, galvanized...

 

Intelligent control panel available – real-time monitoring and remote management

This Perkins diesel generator supports an optional intelligent control panel, enabling full-dimensional real-time monitoring of operating parameters such as voltage, current, frequency, water temperature and oil pressure. It also realizes remote start-stop, fault alarm and data query functions, making the operation and management of the diesel generator more intelligent and efficient, and fully meeting the needs of modern unattended power stations.

 

Compact structure with small footprint – saving space in equipment room or site

Adopting an optimized integrated layout, this Perkins diesel generator features a compact and reasonable structure with a smaller overall size. It effectively reduces the floor area, making it more suitable for compact equipment rooms, limited construction sites and space-constrained installation environments, helping users save valuable site space while ensuring strong power performance.

 

Supports ATS automatic switching – automatic power supply in seconds during power outage

This diesel generator is perfectly compatible with ATS automatic transfer switch devices. Once the mains power is interrupted, it can quickly receive signals and achieve second-level automatic startup and power supply, without manual operation. The seamless switching ensures uninterrupted power supply for critical loads, greatly improving the safety and continuity of industrial and commercial power use.

 

FAQ Section

1. Q: What are the emission standards of the Perkins generator?

A: Small-power models meet China III/EU Stage V standards, while large-power models use high-pressure common rail electronic fuel injection technology to adapt to different regional environmental requirements.

2. Q: Does it support remote monitoring?

A: Yes. Real-time data and historical alarms such as voltage, current, and oil temperature can be viewed on a mobile phone or computer via an IoT module.

3. Q: What is the difference in floor space between the 20kW and 1500kW models?

A: The 20kW open-type generator requires approximately 1.5㎡, while the 1500kW silent type requires approximately 12-15㎡ (including maintenance access), a difference of nearly 10 times. The generator room needs to be planned in advance.

4. Q: Is the Perkins generator suitable for use in high-altitude areas?

A: It can be used normally below 3000 meters. At higher altitudes, power reduction is required (approximately 8-12% derating for every 1000 meters increase in altitude) and turbocharger adjustment.