♦ The 400KW, 460KW, 500KW and 520KW Perkins diesel generator series is designed for large industrial and commercial users with high-standard power demands.
♦ Powered by genuine Perkins engines and matched with high-performance alternators, this diesel generator series delivers stable and strong power output for large factories, data centers, infrastructure facilities and important public sites.
♦ With high reliability and strong adaptability, it has become the preferred high-power power solution for modern power systems.
Product Description | Perkins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-500GFP | AT-550GFP | AT-600GFP | AT-650GFP | AT-700GFP | AT-800GFP | AT-900GFP | AT-1000GFP | |
| Genset Power | KW(=0.8KVA) | 500 | 550 | 600 | 650 | 700 | 800 | 900 | 1000 |
| KVA(=1.25KW) | 625 | 687.5 | 750 | 812.5 | 875 | 1000 | 1125 | 1250 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 98.04 | 107.84 | 117.65 | 127.45 | 137.25 | 156.86 | 176.47 | 196.08 |
| 75% Load (L/h) | 73.53 | 80.88 | 88.24 | 95.59 | 102.94 | 117.65 | 132.35 | 147.06 | |
| 50% Load (L/h) | 49.02 | 53.92 | 58.82 | 63.73 | 68.63 | 78.43 | 88.24 | 98.04 | |
| Fuel Tank Capacity (L) | 600 | 600 | 800 | 800 | 800 | 1000 | 1000 | 1200 | |
| Open Type (L*W*H) |
Demension(mm) | 3500*1400*2100 | 3600*1550*2200 | 4300*1800*2500 | 4300*1800*2500 | 4350*1800*2500 | 4400*1800*2500 | 4450*1800*2500 | 4450*1800*2500 |
| Weight(KG) | 4200 | 4500 | 7100 | 7300 | 7600 | 7800 | 7900 | 8200 | |
| Silent Type (L*W*H) |
Demension(mm) | 4000*1600*2100 | 4000*1600*2100 | 4600*2000*2300 | 4600*2000*2300 | 4600*2200*2300 | 4600*2200*2300 | 5200*2300*2500 | 5200*2300*2500 |
| Weight(KG) | 4750 | 5050 | 7650 | 7850 | 8150 | 8350 | 8450 | 8750 | |
| Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | ||||||||
| Connector Plug |
Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... |
||||||||
| Custom Made | Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | |||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Intelligent control panel available – real-time monitoring and remote management
This Perkins diesel generator supports an optional intelligent control panel, enabling full-dimensional real-time monitoring of operating parameters such as voltage, current, frequency, water temperature and oil pressure. It also realizes remote start-stop, fault alarm and data query functions, making the operation and management of the diesel generator more intelligent and efficient, and fully meeting the needs of modern unattended power stations.
Compact structure with small footprint – saving space in equipment room or site
Adopting an optimized integrated layout, this Perkins diesel generator features a compact and reasonable structure with a smaller overall size. It effectively reduces the floor area, making it more suitable for compact equipment rooms, limited construction sites and space-constrained installation environments, helping users save valuable site space while ensuring strong power performance.
Supports ATS automatic switching – automatic power supply in seconds during power outage
This diesel generator is perfectly compatible with ATS automatic transfer switch devices. Once the mains power is interrupted, it can quickly receive signals and achieve second-level automatic startup and power supply, without manual operation. The seamless switching ensures uninterrupted power supply for critical loads, greatly improving the safety and continuity of industrial and commercial power use.
FAQ Section
1. Q: What are the emission standards of the Perkins generator?
A: Small-power models meet China III/EU Stage V standards, while large-power models use high-pressure common rail electronic fuel injection technology to adapt to different regional environmental requirements.
2. Q: Does it support remote monitoring?
A: Yes. Real-time data and historical alarms such as voltage, current, and oil temperature can be viewed on a mobile phone or computer via an IoT module.
3. Q: What is the difference in floor space between the 20kW and 1500kW models?
A: The 20kW open-type generator requires approximately 1.5㎡, while the 1500kW silent type requires approximately 12-15㎡ (including maintenance access), a difference of nearly 10 times. The generator room needs to be planned in advance.
4. Q: Is the Perkins generator suitable for use in high-altitude areas?
A: It can be used normally below 3000 meters. At higher altitudes, power reduction is required (approximately 8-12% derating for every 1000 meters increase in altitude) and turbocharger adjustment.