♦ We offer 800KW, 900KW, 1000KW full-range high-power Perkins diesel generator models to meet differentiated high-load power demands.
♦ Powered by original imported Perkins engine, this diesel generator features leading high-pressure common rail electronic fuel injection technology, which ensures superior fuel atomization, lower fuel consumption and higher operating efficiency under high-power operation.
♦ Equipped with high-precision electronic speed regulation system, the Perkins diesel generator maintains extremely small frequency fluctuation during sudden load changes, delivering ultra-stable power output for precision industrial equipment. Adopting modular parallel connection design, multiple units of the diesel generator can be flexibly combined and expanded, realizing seamless upgrade to megawatt-level power supply to adapt to growing business needs.
Product Description | Perkins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-500GFP | AT-550GFP | AT-600GFP | AT-650GFP | AT-700GFP | AT-800GFP | AT-900GFP | AT-1000GFP | |
| Genset Power | KW(=0.8KVA) | 500 | 550 | 600 | 650 | 700 | 800 | 900 | 1000 |
| KVA(=1.25KW) | 625 | 687.5 | 750 | 812.5 | 875 | 1000 | 1125 | 1250 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 98.04 | 107.84 | 117.65 | 127.45 | 137.25 | 156.86 | 176.47 | 196.08 |
| 75% Load (L/h) | 73.53 | 80.88 | 88.24 | 95.59 | 102.94 | 117.65 | 132.35 | 147.06 | |
| 50% Load (L/h) | 49.02 | 53.92 | 58.82 | 63.73 | 68.63 | 78.43 | 88.24 | 98.04 | |
| Fuel Tank Capacity (L) | 600 | 600 | 800 | 800 | 800 | 1000 | 1000 | 1200 | |
| Open Type (L*W*H) |
Demension(mm) | 3500*1400*2100 | 3600*1550*2200 | 4300*1800*2500 | 4300*1800*2500 | 4350*1800*2500 | 4400*1800*2500 | 4450*1800*2500 | 4450*1800*2500 |
| Weight(KG) | 4200 | 4500 | 7100 | 7300 | 7600 | 7800 | 7900 | 8200 | |
| Silent Type (L*W*H) |
Demension(mm) | 4000*1600*2100 | 4000*1600*2100 | 4600*2000*2300 | 4600*2000*2300 | 4600*2200*2300 | 4600*2200*2300 | 5200*2300*2500 | 5200*2300*2500 |
| Weight(KG) | 4750 | 5050 | 7650 | 7850 | 8150 | 8350 | 8450 | 8750 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Versatile High-Power Output for Heavy-Duty Industrial Scenarios
Our Perkins diesel generator covers three mainstream high-power models of 800KW, 900KW and 1000KW, delivering stable and high-efficiency power supply for large industrial parks, engineering projects and centralized backup power scenarios. As a high-performance power equipment, this diesel generator adopts authentic Perkins core power, with outstanding durability and adaptive capacity to cope with long-time continuous operation and harsh working conditions, fully meeting the high-load power demand of large-scale industries.
Superior Core Technology Optimizes Overall Operating Efficiency
This high-power Perkins diesel generator is equipped with high-pressure common rail electronic fuel injection technology, which realizes finer fuel atomization, greatly improves combustion sufficiency, and maintains high energy efficiency even under high-power full-load operation. Supported by modular parallel expansion design, multiple units of the 800KW to 1000KW diesel generator can be connected in parallel flexibly, easily expanding the power output to the megawatt level and solving the power supply demand of ultra-large load. Meanwhile, the high-stability electronic speed regulation system configured by Perkins engine effectively suppresses frequency fluctuation during sudden load changes, making the whole diesel generator operate smoothly, and perfectly adapting to precision industrial production and high-precision equipment power supply scenarios.
Stable & Expandable Power Suitable for Diverse Complex Scenarios
Relying on the reliable quality of Perkins brand, the 800KW, 900KW and 1000KW Perkins diesel generator balances strong power output, low fuel consumption and low failure rate. Whether it is factory emergency backup power, remote engineering fixed power supply, or large-scale facility peak shaving power supply, this diesel generator can respond efficiently. The optimized structural design and intelligent control configuration reduce daily maintenance difficulty, and the flexible parallel connection capability brings more flexible power deployment solutions for industrial users, becoming a cost-effective and reliable high-power power guarantee in the industrial field.
FAQ Section
1. Q: What power range does Perkins generator primarily cover?
A: Mature models are available from 20kW to 1500kW, suitable for everything from home emergency power to main power supplies for data centers or mines.
2. Q: What are the core advantages of Perkins generators compared to domestically produced generators?
A: Better fuel economy, stronger cold start capability, longer overhaul intervals (some models exceed 20,000 hours), and lower long-term operating costs.
3. Q: Do Perkins generators support automatic start?
A: Yes. When paired with an ATS (Automatic Transfer Switch), they can automatically start and load within 8-15 seconds after a mains power outage.
4. Q: How much more expensive are silent generator sets compared to open-type units?
A: Typically 30%-50% more expensive, but they reduce noise by 25-35 dB(A), making them suitable for noise-sensitive locations such as residential areas and hospitals.