♦ We offer 800KW, 900KW, 1000KW full-range high-power Perkins diesel generator models to meet differentiated high-load power demands.
♦ Powered by original imported Perkins engine, this diesel generator features leading high-pressure common rail electronic fuel injection technology, which ensures superior fuel atomization, lower fuel consumption and higher operating efficiency under high-power operation.
♦ Equipped with high-precision electronic speed regulation system, the Perkins diesel generator maintains extremely small frequency fluctuation during sudden load changes, delivering ultra-stable power output for precision industrial equipment. Adopting modular parallel connection design, multiple units of the diesel generator can be flexibly combined and expanded, realizing seamless upgrade to megawatt-level power supply to adapt to growing business needs.
Product Description | Perkins-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-500GFP | AT-550GFP | AT-600GFP | AT-650GFP | AT-700GFP | AT-800GFP | AT-900GFP | AT-1000GFP | |
| Genset Power | KW(=0.8KVA) | 500 | 550 | 600 | 650 | 700 | 800 | 900 | 1000 |
| KVA(=1.25KW) | 625 | 687.5 | 750 | 812.5 | 875 | 1000 | 1125 | 1250 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 98.04 | 107.84 | 117.65 | 127.45 | 137.25 | 156.86 | 176.47 | 196.08 |
| 75% Load (L/h) | 73.53 | 80.88 | 88.24 | 95.59 | 102.94 | 117.65 | 132.35 | 147.06 | |
| 50% Load (L/h) | 49.02 | 53.92 | 58.82 | 63.73 | 68.63 | 78.43 | 88.24 | 98.04 | |
| Fuel Tank Capacity (L) | 600 | 600 | 800 | 800 | 800 | 1000 | 1000 | 1200 | |
| Open Type (L*W*H) |
Demension(mm) | 3500*1400*2100 | 3600*1550*2200 | 4300*1800*2500 | 4300*1800*2500 | 4350*1800*2500 | 4400*1800*2500 | 4450*1800*2500 | 4450*1800*2500 |
| Weight(KG) | 4200 | 4500 | 7100 | 7300 | 7600 | 7800 | 7900 | 8200 | |
| Silent Type (L*W*H) |
Demension(mm) | 4000*1600*2100 | 4000*1600*2100 | 4600*2000*2300 | 4600*2000*2300 | 4600*2200*2300 | 4600*2200*2300 | 5200*2300*2500 | 5200*2300*2500 |
| Weight(KG) | 4750 | 5050 | 7650 | 7850 | 8150 | 8350 | 8450 | 8750 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Product Description
Versatile High-Power Output for Heavy-Duty Industrial Scenarios
Our Perkins diesel generator covers three mainstream high-power models of 800KW, 900KW and 1000KW, delivering stable and high-efficiency power supply for large industrial parks, engineering projects and centralized backup power scenarios. As a high-performance power equipment, this diesel generator adopts authentic Perkins core power, with outstanding durability and adaptive capacity to cope with long-time continuous operation and harsh working conditions, fully meeting the high-load power demand of large-scale industries.
Superior Core Technology Optimizes Overall Operating Efficiency
This high-power Perkins diesel generator is equipped with high-pressure common rail electronic fuel injection technology, which realizes finer fuel atomization, greatly improves combustion sufficiency, and maintains high energy efficiency even under high-power full-load operation. Supported by modular parallel expansion design, multiple units of the 800KW to 1000KW diesel generator can be connected in parallel flexibly, easily expanding the power output to the megawatt level and solving the power supply demand of ultra-large load. Meanwhile, the high-stability electronic speed regulation system configured by Perkins engine effectively suppresses frequency fluctuation during sudden load changes, making the whole diesel generator operate smoothly, and perfectly adapting to precision industrial production and high-precision equipment power supply scenarios.
Stable & Expandable Power Suitable for Diverse Complex Scenarios
Relying on the reliable quality of Perkins brand, the 800KW, 900KW and 1000KW Perkins diesel generator balances strong power output, low fuel consumption and low failure rate. Whether it is factory emergency backup power, remote engineering fixed power supply, or large-scale facility peak shaving power supply, this diesel generator can respond efficiently. The optimized structural design and intelligent control configuration reduce daily maintenance difficulty, and the flexible parallel connection capability brings more flexible power deployment solutions for industrial users, becoming a cost-effective and reliable high-power power guarantee in the industrial field.
Product Advantages
Modular Design and Integration Efficiency
The 800kw perkins diesel generator features a modular parallel connection design that enables seamless integration with additional units such as the 900kw 1000kw perkins generator, allowing scalable power expansion. Its structural engineering incorporates durable components optimized for continuous operation under heavy-duty industrial conditions. The design flexibility supports various configurations, including silent type or open type units, and customizable fuel tanks and trailers. As a high power perkins diesel generator manufacturer, we ensure these systems are engineered to enhance installation compatibility and reduce maintenance complexity, meeting the rigorous demands of modern technical infrastructures.
Superior Operational Performance and User Interface
Performance-wise, the generator delivers consistent frequency stability and fuel efficiency driven by Perkins’ advanced fuel injection technology, maximizing uptime and reducing operational costs. User operability is enhanced through options like remote control via mobile apps and automatic transfer systems, facilitating prompt response during power interruptions. The 800kw perkins diesel generator’s noise-reducing silent versions contribute to quieter environments without sacrificing power output. These performance and usability aspects combine to create a reliable energy solution that supports critical industrial workflows and user requirements for dependable power delivery.
Use Scenarios
Power Backup for Healthcare and Data Centers
In environments such as hospitals and data centers, uninterrupted power is non-negotiable. The 800kw perkins diesel generator serves as a primary emergency power source, ensuring critical systems remain operational during grid outages. Its stable and ultra-steady power output, aligned with international safety standards, supports sensitive equipment operation under sudden load changes. Integration with automatic transfer switches allows swift, autonomous transition between grid and generator power, minimizing downtime and protecting data integrity and patient safety. This solution is ideal for institutions requiring guaranteed power continuity and compliance with regulatory frameworks, benefiting from the expertise of a high power perkins diesel generator manufacturer.
Grid Support and Industrial Peak Load Management
Large manufacturing facilities and utilities frequently contend with power fluctuations and peak demand challenges. The 800kw perkins diesel generator offers supplemental grid connection support to stabilize local power supply and execute peak load shaving strategies. By enabling parallel operations with other generators including the 900kw 1000kw perkins generator, it helps optimize energy distribution and reduces strain on primary infrastructure. This application improves operational resilience and energy cost efficiency in industrial environments, while its robust design ensures reliability in continuous, heavy-load applications. The generator’s adaptability also facilitates integration with existing energy management systems.
FAQ
What power range does Perkins generator primarily cover?
Mature models are available from 20kW to 1500kW, suitable for everything from home emergency power to main power supplies for data centers or mines.
What are the core advantages of Perkins generators compared to domestically produced generators?
Better fuel economy, stronger cold start capability, longer overhaul intervals (some models exceed 20,000 hours), and lower long-term operating costs.
Do Perkins generators support automatic start?
Yes. When paired with an ATS (Automatic Transfer Switch), they can automatically start and load within 8-15 seconds after a mains power outage.
How much more expensive are silent generator sets compared to open-type units?
Typically 30%-50% more expensive, but they reduce noise by 25-35 dB(A), making them suitable for noise-sensitive locations such as residential areas and hospitals.