Ricardo
Ricardo
1000KW Ricardo Diesel Generator
1000KW Ricardo Diesel Generator

1000KW Ricardo Diesel Generator

Product Introduction

Megawatt-Level Power Core
The 1000KW Ricardo diesel generator set features an original Ricardo V16/V18 four-stroke diesel engine with two-stage turbocharging and sectionalized high-pressure common rail technology, achieving fuel consumption as low as 205g/kWh. This Ricardo diesel generator is specifically designed for supercomputing centers, large-scale refineries, and national-level emergency power stations.

♦ Triple Cooling Redundancy
Standard three independent circulation cooling systems (main water jacket + secondary intercooler + oil cooler) allow the remaining systems to maintain 80% load operation if any one circulation fails. The generator features H-class insulated all-copper windings and anti-condensation heaters, with the stator treated by vacuum pressure impregnation to withstand coastal high salt spray and inland sandstorm environments.

♦ Intelligent Grid-Connected Black Start
Built-in synchronizing grid-connected controller and black start module support ring-type paralleling of up to 16 units (total output 16MW), with self-starting and grid establishment capabilities without external power. This diesel generator offers optional containerized soundproof units, widely used in grid black start, island microgrids, and major event power protection.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Ricardo-Diesel Generator  Technical Parameters
Genset Model AT-500GFR AT-550GFR AT-600GFR AT-650GFR AT-700GFR AT-800GFR AT-900GFR AT-1000GFR
Genset Power KW(=0.8KVA) 500 550 600 650 700 800 900 1000
KVA(=1.25KW) 625 687.5 750 812.5 875 1000 1125 1250
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 98.04  107.84  117.65  127.45  137.25  156.86  176.47  196.08 
75% Load (L/h) 73.53  80.88  88.24  95.59  102.94  117.65  132.35  147.06 
50% Load (L/h) 49.02  53.92  58.82  63.73  68.63  78.43  88.24  98.04 
Fuel Tank Capacity (L) 600 600 800 800 800 1000 1000 1200
Open Type
(L*W*H)
Demension(mm) 3500*1400*2100 3600*1550*2200 4300*1800*2500 4300*1800*2500 4350*1800*2500 4400*1800*2500 4450*1800*2500 4450*1800*2500
Weight(KG) 4200 4500 7100 7300 7600 7800 7900 8200
Silent Type
(L*W*H)
Demension(mm) 4000*1600*2100 4000*1600*2100 4600*2000*2300 4600*2000*2300 4600*2200*2300 4600*2200*2300 5200*2300*2500 5200*2300*2500
Weight(KG) 4750 5050 7650 7850 8150 8350 8450 8750
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material Cast iron, stainless steel, galvanized...

 

Optional Deepsea and Smartgen Controllers
The Ricardo diesel generator can be equipped with Deepsea, Smartgen and other mainstream intelligent controllers as standard or optional accessories. This intelligent diesel generator integrates complete data monitoring and intelligent management functions, stably realizing remote real-time monitoring and automatic fault diagnosis during operation. Operators can remotely check various operating parameters and quickly locate equipment faults, greatly simplifying daily inspection and maintenance work. With diversified intelligent control configurations from Ricardo, the unit realizes unattended safe operation, effectively improving overall operating efficiency and reducing manual management pressure in large power supply projects.

 

8-10 Hours Endurance with Base Fuel Tank
This high-power Ricardo diesel generator is fitted with large-capacity integrated base fuel tank, which can support continuous full-load operation for 8 to 10 hours steadily. This practical design effectively lowers frequent refueling needs in outdoor and remote working sites. This long-endurance diesel generator is perfectly suitable for uninterrupted power supply scenarios where fuel replenishment is inconvenient. Optimized internal oil supply pipeline design of Ricardo ensures smooth and stable fuel delivery, keeps the unit running continuously for a long time, and effectively guarantees stable power output progress for field engineering and large-scale industrial production.

 

Standard Reserved ATS Automatic Transfer Interface
The Ricardo diesel generator reserves dedicated ATS automatic switching interface by default, which is convenient for users to install matching automatic switching system. Once the municipal power supply is cut off, the unit can start up rapidly and connect loads automatically within 10 to 15 seconds. This highly responsive emergency diesel generator achieves seamless power switching and effectively avoids production shutdown and equipment damage caused by sudden power failure. With stable signal induction and quick start performance of Ricardo, it provides solid and reliable emergency power guarantee for key places that require uninterrupted power supply all year round.

 

Multiple Optional Voltage Output Modes
The Ricardo diesel generator boasts rich voltage output options to meet global diverse power standards. It covers common low voltage such as 380V, 400V, 415V and 480V, and is also compatible with medium voltage output of 10.5kV and 13.8kV. This highly adaptable diesel generator can flexibly match power demands of different countries, regions and various industrial equipment. With flexible electrical parameter configuration advantages of Ricardo, it can perfectly adapt to civil commercial power, industrial high-power power supply and large-scale grid-connected power generation projects, bringing more convenient and targeted power matching solutions for global users.

 

FAQ Section

1. Q: What starting method does the Ricardo high-power generator set use?

A: A 24V electric start system is standard, with an optional ATS automatic start system. A cylinder heater can be installed for low-temperature environments to ensure cold start reliability.

 

2. Q: What items should be considered during the daily inspection of Ricardo high-power generator sets?

A: Daily checks should focus on:

Engine oil level (should be between the upper and lower marks on the dipstick)

Coolant level (within the specified range for the expansion tank)

Fuel tank level

Exterior inspection for leaks or damage

Battery status and wiring

 

3. Q: What is the warranty period for Ricardo generator sets?

A: The standard warranty period is 12 months or 1000 hours of operation (whichever comes first), with lifetime technical support.

 

4. Q: Are Ricardo generator sets suitable for harsh environments such as mining areas?

A: Yes. The open-frame design is simple and has good heat dissipation, making it suitable for dusty environments such as mining areas and construction sites. The unit uses a high-strength steel chassis and shock-absorbing design, which can withstand a certain degree of vibration and impact.

 

Please fill in the following information and submit it before downloading the file