Ricardo
Ricardo
100KW Ricardo  Diesel Generator 120KW 150KW 160KW
100KW Ricardo  Diesel Generator 120KW 150KW 160KW

100KW Ricardo Diesel Generator 120KW 150KW 160KW

Product Introduction

Electronically Controlled High-Pressure Common Rail
The 100-160KW Ricardo diesel generator set (including 120KW, 150KW) features an electronically controlled high-pressure common rail fuel system with injection pressure of 1600 bar, achieving cleaner combustion and lower emissions. This Ricardo diesel generator is suitable for medium-sized processing plants, hospital backup power, and small data centers.

Efficient Cooling System
Standard large-capacity multi-channel radiator and temperature-controlled fan enable continuous full-load operation at 40°C ambient temperature without overheating. The generator features H-class insulated all-copper windings and a brushless excitation system, with 110% overload capacity for 1 hour, suitable for motor loads with frequent starts.

Intelligent Monitoring & Protection
The control panel features an LCD display showing real-time voltage, frequency, oil pressure, coolant temperature, and runtime. This diesel generator has built-in fault self-diagnosis capability and supports an RS485 communication interface for integration into building automation systems (BAS), enabling remote monitoring and management.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
Ricardo-Diesel Generator  Technical Parameters
Genset Model AT-80GFR AT-90GFR AT-100GFR AT-110GFR AT-120GFR AT-130GFR AT-140GFR AT-150GFR
Genset Power KW(=0.8KVA) 80 90 100 110 120 130 140 150
KVA(=1.25KW) 100 112.5 125 137.5 150 162.5 175 187.5
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 15.69  17.65  19.61  21.57  23.53  25.49  27.45  29.41 
75% Load (L/h) 11.76  13.24  14.71  16.18  17.65  19.12  20.59  22.06 
50% Load (L/h) 7.84  8.82  9.80  10.78  11.76  12.75  13.73  14.71 
Fuel Tank Capacity (L) 100 100 100 160 160 160 200 200
Open Type
(L*W*H)
Demension(mm) 2250*800*1450 2250*900*1500 2250*900*1500 2300*950*1500 2300*950*1500 2300*950*1500 2400*1050*1600 2400*1050*1600
Weight(KG) 980 1050 1100 1200 1300 1400 1600 1700
Silent Type
(L*W*H)
Demension(mm) 2600*1100*1500 2800*1100*1500 2800*1100*1500 2800*1100*1500 2900*1100*1700 2900*1100*1700 2900*1100*1700 3000*1100*1700
Weight(KG) 1380 1450 1500 1600 1700 1800 2000 2100
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material Cast iron, stainless steel, galvanized...

 

Flexible Custom Voltage Design
The Ricardo diesel generator supports wide voltage customization ranging from 110V to 13.8kV, and can be tailored for both 50Hz and 60Hz working frequency freely. This practical diesel generator can perfectly match power supply standards of different countries and regions all over the world. No matter it is daily civil power, commercial power or industrial high-voltage power demand, it can realize accurate parameter matching. With strong parameter adjustment capability of Ricardo, the unit is highly compatible with overseas export projects and cross-regional engineering construction, greatly simplifying user’s power scheme matching and site commissioning work.

 

Multiple Safety Protection Functions
This Ricardo diesel generator is built in complete safety protection systems as standard configuration. It comes with overload protection, undervoltage protection and automatic shutdown function at low oil level and other practical safety designs. This reliable diesel generator can effectively avoid equipment damage caused by abnormal power supply and improper operation. Once abnormal working status occurs, the unit will respond rapidly to cut off operation for self-protection. With comprehensive safety guard from Ricardo, it effectively lowers operation risks, prolongs service life and ensures safe and stable long-term running in various industrial and commercial application scenes.

 

All-Copper Brushless AC Alternator
The Ricardo diesel generator adopts high-quality all-copper brushless alternator with 100% pure copper winding and Class H insulation level. Equipped with brushless self-excitation design and built-in AVR voltage stabilization device, this premium diesel generator owns outstanding power output stability and strong anti-interference ability. It features low heat generation, high working efficiency and stable voltage fluctuation control. Optimized core power matching of Ricardo ensures steady power output under variable loads, suitable for long-time continuous power supply and important load standby power use in various medium and large power demand occasions.

 

FAQ Section

1. Q: What are the functions of the Ricardo generator set control panel?

A: Ricardo generator sets come standard with an LCD digital display control panel. Main functions include:

Parameter Display: Voltage, current, frequency, oil pressure, water temperature, operating hours, battery voltage

Protection Functions: Low oil pressure alarm shutdown, high water temperature alarm shutdown, overspeed protection, overload protection, undervoltage protection

Control Modes: Manual/Automatic/Remote start, optional ATS automatic switching

 

2. Q: What is the warranty period for Ricardo generator sets?

A: Ricardo generator sets typically offer a one-year global warranty and lifetime technical support. Some suppliers may also offer extended warranties; please confirm with your procurement channel for details. The warranty covers major components of the engine, generator, and control system.

 

3. Q: Does the Ricardo generator set support ATS automatic transfer switch?

A: Yes. Ricardo generator sets can be equipped with an ATS automatic transfer switch cabinet, enabling automatic start-up after a mains power outage, automatic power restoration, and automatic shutdown after mains power is restored. Switching time is typically within 10-15 seconds, suitable for emergency power supply to critical loads such as data centers, hospitals, and base stations.

 

4. Q: What are the routine maintenance requirements for Ricardo generator sets?

A: Basic maintenance of Ricardo generator sets includes:

Daily/Pre-operation: Check engine oil level, coolant level, fuel level, appearance, and for leaks.

Weekly: Run the generator under no-load for 10-15 minutes to check battery status.

Every 250 hours: Change engine oil, oil filter, and diesel filter.

Regular checks: Air filter, belt tension, valve clearance, and injector condition.

Cleaning: Regularly clean external mud and radiator fins.

 

Please fill in the following information and submit it before downloading the file