Volvo
Volvo
100KW Volvo Diesel Generator 120KW 150KW 160KW
100KW Volvo Diesel Generator 120KW 150KW 160KW

100KW Volvo Diesel Generator 120KW 150KW 160KW

Product Introduction

♦ The 100-160KW Volvo diesel generator set (including 120KW, 150KW) features high-pressure common rail and dual overhead camshaft technology, reducing combustion noise by 3dB(A). This Volvo diesel generator is suitable for noise-sensitive locations such as hospitals, high-end residences, and commercial complexes.

 

♦ Built-in dynamic speed control module delivers transient frequency deviation below 3% when load suddenly increases from 0% to 80%, with recovery time of just 1.5 seconds. The generator features fully sealed waterproof terminals and reinforced bearings, suitable for long-term operation in environments with humidity up to 98%.

 

♦ With a width of only 1.2 meters, the unit reduces floor space by 20% compared to similar products, allowing easy passage through standard fire doors. This diesel generator comes standard with a large-capacity base fuel tank (8 hours continuous operation) and offers an optional external fuel tank with automatic refill system.

Main Functions
Main/Prime Power Supply
Main/Prime Power Supply
Backup Power Supply
Backup Power Supply
Emergency Power Supply
Emergency Power Supply
Grid Connection Support
Grid Connection Support
Product Description
VOLVO-Diesel Generator  Technical Parameters
Genset Model AT-80GFV AT-90GFV AT-100GFV AT-110GFV AT-120GFV AT-130GFV AT-140GFV AT-150GFV
Genset Power KW(=0.8KVA) 80 90 100 110 120 130 140 150
KVA(=1.25KW) 100 112.5 125 137.5 150 162.5 175 187.5
Voltage Single-phase (V) 110V(L+N)   120V(L+N)   127V(L+N)    220V (L+N)    220/110V (L+L+N)   240/120V (L+L+N)
Three-phase (V) 208/120V   220/127V   240/139V  380/220V   400/230V   415/240V   440/254V   460/266V   480/277V
Frequency and Speed 50Hz/1500RPM  60HZ/1800RPM
Alternator Brand Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU
Controller Brand Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay
Fuel consumption 100% Load (L/h) 15.69  17.65  19.61  21.57  23.53  25.49  27.45  29.41 
75% Load (L/h) 11.76  13.24  14.71  16.18  17.65  19.12  20.59  22.06 
50% Load (L/h) 7.84  8.82  9.80  10.78  11.76  12.75  13.73  14.71 
Fuel Tank Capacity (L) 100 100 100 160 160 160 200 200
Open Type
(L*W*H)
Demension(mm) 2250*800*1450 2250*900*1500 2250*900*1500 2300*950*1500 2300*950*1500 2300*950*1500 2400*1050*1600 2400*1050*1600
Weight(KG) 980 1050 1100 1200 1300 1400 1600 1700
Silent Type
(L*W*H)
Demension(mm) 2600*1100*1500 2800*1100*1500 2800*1100*1500 2800*1100*1500 2900*1100*1700 2900*1100*1700 2900*1100*1700 3000*1100*1700
Weight(KG) 1380 1450 1500 1600 1700 1800 2000 2100
Custom Made Remote Operation Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software
Connector Plug Basic: Circuit Breaker;  Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks.....
Color Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000......
Fuel tank Basic: 8-10 hours;  Optional: 200L, 300L, 400L, 500L, 600L......1000L
Trailer 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)...
Material Cast iron, stainless steel, galvanized...

 

Versatile Power Solution for Industrial and Commercial Users
This 100KW, 120KW, 150KW and 160KW Volvo diesel generator is engineered to deliver high-reliability power for commercial facilities, industrial parks, municipal engineering and critical backup power scenarios. Suitable for facility managers, construction projects and data center power planners, this diesel generator provides stable power support during grid interruptions and remote off-grid operation. With multiple power specifications available, the Volvo diesel generator offers scalable power options to match different load demands, perfectly meeting professional engineering configuration and procurement requirements.

 

Advanced Technical Configuration and Outstanding Comprehensive Performance
Adopting fully electronic fuel injection engine technology, this Volvo diesel generator achieves an overhaul interval of over 30,000 hours, leading the industry in maintenance-free service time and effectively reducing the full life-cycle maintenance cost of the diesel generator. Equipped with intake manifold electric heater and intelligent preheating device, the unit realizes reliable cold startup at -12℃ without auxiliary equipment, ensuring fast winter low-temperature startup and lowering the failure risk of standby power supply. It strictly complies with ISO 8528 G3 highest-grade transient response standard, achieving second-level full-load power supply after power outage, fully safeguarding the continuous and stable operation of data centers and high-precision key loads.

 

Applications Spanning Multiple High-End Critical Power Sectors
This premium Volvo diesel generator is widely used as emergency backup power for data centers, manufacturing plants, commercial office buildings and hospital systems, maintaining uninterrupted workflow during sudden power outages. It also acts as prime power for construction, mining and remote field sites with harsh working conditions and high reliability standards. With long overhaul cycle, excellent low-temperature startup performance and G3-grade transient response capability, the diesel generator meets strict international industry standards. Optional open and silent enclosure designs further enhance environmental adaptability, making the Volvo diesel generator an ideal high-end power solution for occasions requiring high stability, high safety and long-term reliable operation.

 

FAQ Section

1. Q: What is the difference in maintenance between the primary generator set and the standby generator set?

A: The primary generator set (operating day and night) requires strict maintenance based on hourly cumulative maintenance. It is recommended to change the oil filter and diesel filter every 250-300 hours of operation, and perform a third-level maintenance after 1000 hours. The standby unit (which may only run once a month) can have more leeway. A comprehensive inspection of water, electricity, oil, and gas should be conducted every six months or one year, followed by a 5-10 minute no-load test. The three filters (air filter, fuel filter, and air filter) should be replaced every two years.

 

2. Q: Can Volvo generators achieve automatic start and parallel operation?

A: Yes. Volvo generator sets, when used with an ATS (Automatic Transfer Switch), can achieve a full set of functions: automatic start, automatic power supply, and automatic shutdown after mains power restoration in case of an anomaly. Two or more units can also be connected in parallel and the load can be evenly distributed through a paralleling panel to meet expansion or redundant power supply needs. In addition, Volvo diesel generators are equipped with an automatic start control panel, supporting local manual and automatic control modes.

 

3. Q: Are Volvo generators noisy? Can a soundproof enclosure be installed?

A: Volvo generators themselves have low vibration and low noise. Taking a 500kW unit as an example, the noise level can be reduced to approximately 60-75 decibels when operating in a standard generator room. A silencer and closed-loop water cooling system are standard. For further noise reduction, a customized silent housing is available as an option. Through a split cooling system, high-efficiency muffler, and sealed soundproof chamber, noise levels can be controlled to 60-75 dB(A) (1 meter from the unit), meeting the requirements of urban environmental protection zones or indoor installation.

 

4. Q: Can the Volvo generator's control panel be remotely monitored?

A: Yes. Volvo generators are equipped with an automatic start-up control panel. An optional fully automatic control panel with "three-remote" (telemetry, remote signaling, and remote control) functions is available, enabling remote or off-site monitoring via data cable or the internet. It also supports GPS positioning and mobile phone SMS monitoring. The control system can display parameters such as three-phase voltage, current, frequency, engine speed, oil pressure, coolant temperature, and battery voltage in real time, and provides multiple protection functions such as overcoolant temperature, underoil pressure, overspeed, and overvoltage protection.

 