♦ The 200-280KW Volvo diesel generator set (including 220KW, 240KW) features electronic unit pumps and wastegate turbocharging, increasing low-speed torque by 25% for stronger load acceptance. This Volvo diesel generator is especially suitable for equipment with frequent start-stop cycles such as cranes and air compressors.
♦ Independent water jacket cooling and intercooler temperature control loops enable full-load operation without power derating at 50°C ambient temperatures. The generator features patented anti-corona windings and IP23 protection, providing stable output in dusty and high-humidity factory environments.
♦ Built-in CAN bus paralleling interface supports automatic synchronization and load sharing among up to 8 units. This diesel generator offers an optional mobile app for real-time monitoring of oil pressure, coolant temperature, load rate, and fault records, as well as remote emergency shutdown capability.
Product Description | VOLVO-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-160GFV | AT-180GFV | AT-200GFV | AT-250GFV | AT-300GFV | AT-320GFV | AT-360GFV | AT-400GFV | |
| Genset Power | KW(=0.8KVA) | 160 | 180 | 200 | 250 | 300 | 320 | 360 | 400 |
| KVA(=1.25KW) | 200 | 225 | 250 | 312.5 | 375 | 400 | 450 | 500 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 31.37 | 35.29 | 39.22 | 49.02 | 58.82 | 62.75 | 70.59 | 78.43 |
| 75% Load (L/h) | 23.53 | 26.47 | 29.41 | 36.76 | 44.12 | 47.06 | 52.94 | 58.82 | |
| 50% Load (L/h) | 15.69 | 17.65 | 19.61 | 24.51 | 29.41 | 31.37 | 35.29 | 39.22 | |
| Fuel Tank Capacity (L) | 200 | 200 | 280 | 300 | 500 | 500 | 600 | 600 | |
| Open Type (L*W*H) |
Demension(mm) | 2500*1050*1700 | 2500*1050*1700 | 2600*1050*1700 | 2700*1150*1700 | 2750*1150*1700 | 2750*1150*1700 | 3200*1370*1900 | 3200*1370*1900 |
| Weight(KG) | 1750 | 1900 | 2000 | 2100 | 2300 | 2800 | 3150 | 3200 | |
| Silent Type (L*W*H) |
Demension(mm) | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 | 3000*1100*1700 |
| Weight(KG) | 1750 | 1900 | 2000 | 2100 | 2300 | 2800 | 3150 | 3200 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Versatile Power Solution for Industrial and Commercial Users
This 200KW, 220KW, 240KW and 280KW Volvo diesel generator is professionally designed to deliver stable and premium power output for large industrial plants, commercial complexes, municipal projects and critical backup power scenarios. It perfectly supports facility managers, construction sites and power backup planners to maintain normal operation during grid outages and remote off-grid conditions. With multiple power ratings to choose from, this Volvo diesel generator provides scalable configuration options to fit various load demands, while flexible open and silent type designs enable the diesel generator to adapt to conventional industrial and commercial installation environments effortlessly.
Advanced Technical Configuration and Eco-Friendly Performance
This Volvo diesel generator adopts mature IP23 protection grade together with professional vibration damping and noise reduction structure, fully meeting conventional installation and operating standards for industrial and commercial scenarios. Equipped with proprietary V-ACT combustion technology and precise EGR exhaust gas recirculation control system, the diesel generator effectively reduces nitrogen oxide formation, striking a perfect balance between high combustion efficiency and low emission performance. The unit fully complies with Euro II and Euro III emission standards as well as EU and EPA environmental regulations, featuring low nitrogen oxides, low particulate matter and low CO₂ comprehensive emissions, making the Volvo diesel generator eco-friendly and compliant for global deployment.
Applications Spanning Multiple Industrial and Commercial Sectors
This high-spec Volvo diesel generator serves as reliable emergency backup power for manufacturing workshops, data centers, commercial buildings and public facilities, ensuring uninterrupted power supply during power failures. It also acts as main temporary power for engineering construction, mining areas and remote stations. With standard IP23 protection, excellent vibration and noise suppression, advanced V-ACT combustion system and full EU/EPA emission compliance, this diesel generator meets strict international environmental and operational requirements. Its outstanding comprehensive performance makes the Volvo diesel generator a preferred high-end power solution for commercial, industrial and environmentally regulated projects worldwide.
FAQ Section
1. Q: Will the performance of Volvo generators decrease at high altitudes?
A: Volvo uses advanced fuel injection and low-resistance intake systems, significantly reducing power loss in high-altitude areas. At an altitude of 5000 meters, power loss is only about 16%, and the power decrease is ≤2.5% for every 1000 meters increase in altitude, far superior to the approximately 8-10% loss rate of similar non-turbocharged models.
2. Q: How is the fuel economy of Volvo generator sets?
A: Fuel economy is outstanding. Taking a 500kW unit as an example, using electronic fuel injection technology, fuel consumption is ≤202g/kW·h, and fuel consumption at full load is approximately 101 liters per hour. The design of an inline six-cylinder, turbocharged intercooled, high-pressure common rail electronic fuel injection system reduces fuel consumption by approximately 5-10% compared to traditional models at the same power output.
3. Q: What is the turbocharging method of Volvo generator sets? What is the difference between TAD and TWD?
A: Volvo diesel engines come standard with an exhaust gas turbocharging system and are available in two intercooling types. The TAD type uses air-to-air intercooling, while the TWD type uses water-to-air intercooling. TAD (Transport Air Cooling) uses air cooling to lower the temperature of the boosted air, making it suitable for areas with stable ambient temperatures; TWD (Transport Water Cooling) uses water cooling to lower the temperature of the boosted air, resulting in higher heat dissipation efficiency and making it suitable for high-load operating conditions.
4. Q: When is the first major overhaul interval for Volvo generator sets?
A: Volvo is renowned in the industry for its high reliability, with overhaul-free operating time well exceeding 30,000 hours. According to operational data and operation and maintenance manuals, there are many cases where the first major overhaul is only required after more than 25,000 hours of operation. Achieving such a long lifespan is key to using genuine parts, standardized operation, and timely maintenance.