♦ The 60-90KW Volvo diesel generator set (including 75KW, 80KW) features an original Volvo engine with electronically controlled high-pressure common rail and wastegate turbocharging technology, achieving fuel consumption as low as 209g/kWh. This Volvo diesel generator is particularly suitable for high-end manufacturing and data center backup power.
♦ Optimized intake/exhaust system and high-compression ratio pistons enable the unit to start and reach full load within 10 seconds. The generator features permanent magnet excitation and a digital AVR, increasing nonlinear load capability by 30%, making it ideal for precision instruments and communication equipment.
♦ Modular cylinder heads and replaceable wet cylinder liners provide an overhaul interval of up to 25,000 hours. This diesel generator comes standard with a low-temperature auxiliary start device (reliable ignition at -15°C), with an optional intelligent remote monitoring module for real-time maintenance reminders and fault alerts.
Product Description | VOLVO-Diesel Generator Technical Parameters | |||||||||
| Genset Model | AT-80GFV | AT-90GFV | AT-100GFV | AT-110GFV | AT-120GFV | AT-130GFV | AT-140GFV | AT-150GFV | |
| Genset Power | KW(=0.8KVA) | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 |
| KVA(=1.25KW) | 100 | 112.5 | 125 | 137.5 | 150 | 162.5 | 175 | 187.5 | |
| Voltage | Single-phase (V) | 110V(L+N) 120V(L+N) 127V(L+N) 220V (L+N) 220/110V (L+L+N) 240/120V (L+L+N) | |||||||
| Three-phase (V) | 208/120V 220/127V 240/139V 380/220V 400/230V 415/240V 440/254V 460/266V 480/277V | ||||||||
| Frequency and Speed | 50Hz/1500RPM 60HZ/1800RPM | ||||||||
| Alternator Brand | Stamford / Leroy-Somer / Marathon / Mecc Alte / ENGGA / KOHLER / Siemens / ABB / AOTEMU | ||||||||
| Controller Brand | Deep Sea- DSE / ComAp / DEIF / SmartGen / Mebay | ||||||||
| Fuel consumption | 100% Load (L/h) | 15.69 | 17.65 | 19.61 | 21.57 | 23.53 | 25.49 | 27.45 | 29.41 |
| 75% Load (L/h) | 11.76 | 13.24 | 14.71 | 16.18 | 17.65 | 19.12 | 20.59 | 22.06 | |
| 50% Load (L/h) | 7.84 | 8.82 | 9.80 | 10.78 | 11.76 | 12.75 | 13.73 | 14.71 | |
| Fuel Tank Capacity (L) | 100 | 100 | 100 | 160 | 160 | 160 | 200 | 200 | |
| Open Type (L*W*H) |
Demension(mm) | 2250*800*1450 | 2250*900*1500 | 2250*900*1500 | 2300*950*1500 | 2300*950*1500 | 2300*950*1500 | 2400*1050*1600 | 2400*1050*1600 |
| Weight(KG) | 980 | 1050 | 1100 | 1200 | 1300 | 1400 | 1600 | 1700 | |
| Silent Type (L*W*H) |
Demension(mm) | 2600*1100*1500 | 2800*1100*1500 | 2800*1100*1500 | 2800*1100*1500 | 2900*1100*1700 | 2900*1100*1700 | 2900*1100*1700 | 3000*1100*1700 |
| Weight(KG) | 1380 | 1450 | 1500 | 1600 | 1700 | 1800 | 2000 | 2100 | |
| Custom Made | Remote Operation | Mobile APP(4G+WIFI) / Computer Software / Mobile APP(4G+WIFI) + Computer Software | |||||||
| Connector Plug | Basic: Circuit Breaker; Optional: ATS, CEE Plugs, Twist Plugs, Sockets, Cam Locks..... | ||||||||
| Color | Customized according to RAL international color chart: such as RAL 1000, RAL 2000, RAL 3001RAL 5000...... | ||||||||
| Fuel tank | Basic: 8-10 hours; Optional: 200L, 300L, 400L, 500L, 600L......1000L | ||||||||
| Trailer | 2-wheels trailer, 4-wheels trailer, standard trailer(25 km/h), high-speed trailer(80 km/h), high-speed trailer(110 km/h)... | ||||||||
| Material | Cast iron, stainless steel, galvanized... | ||||||||
Versatile Power Solution for Industrial and Commercial Users
This 60KW, 75KW, 80KW and 90KW Volvo diesel generator is designed to deliver premium and reliable power for industrial facilities, commercial projects, construction sites and emergency backup applications. Ideal for facility managers, project contractors and power backup planners, this diesel generator delivers stable power supply during grid outages and in remote off-grid locations. With multiple power ratings available, the Volvo diesel generator provides flexible scalable options to match diverse load demands, perfectly meeting professional procurement and engineering system configuration requirements.
Advanced Technical Configuration and Superior Fuel Economy
Equipped with genuine imported Volvo Penta diesel engine, this Volvo diesel generator guarantees strict product consistency and complete supporting documents including origin certificates, commodity inspection and customs declaration files. The unit features outstanding fuel efficiency, with fuel consumption rate controlled within 206g/kWh and the lowest reaching 194g/kWh, achieving remarkable savings especially under half-load operation and greatly reducing long-term operating expenses. Optimized with upgraded high-pressure common rail fuel injection system, the D17 engine version saves an additional 5% fuel compared with the D16 model, lowering fuel consumption per kilowatt-hour and realizing continuous iteration and improvement in energy-saving performance for this high-efficiency diesel generator.
Reliable Performance for Wide Application Scenarios
This premium Volvo diesel generator is widely used for emergency backup power in factories, commercial buildings, hospitals and municipal facilities, ensuring uninterrupted operation during power failures. It also serves as prime power for construction, mining and remote working sites with strict quality and efficiency requirements. Thanks to genuine Volvo core power, stable fuel-saving performance and complete import certification, this diesel generator meets international industry standards and environmental norms. Optional open and silent type configurations further expand its applicability, making the Volvo diesel generator a trustworthy high-end power solution demanding stable output, low fuel consumption and formal import qualification.
FAQ Section
1. Q: What is the relationship between Volvo generators and Volvo cars? Does the brand have a long history?
A: Volvo generators are produced by the Volvo Penta brand, a subsidiary of the Volvo Group. Founded in 1927, the Volvo Group is Sweden's largest industrial company, with over 120 years of engine manufacturing history. It is also the world's only manufacturer specializing in inline four-cylinder and six-cylinder diesel engines, holding a leading position in this technology.
2. Q: What is the power range of Volvo generators?
A: Power ranges from 64kW to 550kW (approximately 80kVA to 688kVA), with some models expandable to 600kW or even 700kW. Commonly used models include KH-150GF (150kW), KH-200GF (200kW), KH-300GF (300kW), KH-450GF (456kW), and KH-500GF (505kW), meeting various needs from commercial emergency use to primary industrial applications.
3. Q: What are the core advantages of Volvo generators?
A: The core advantages can be summarized as "one low and three highs"—low fuel consumption (fuel consumption ≤202g/kW·h), high reliability (30,000 hours without major overhaul), high transient response capability (G3 level sudden load performance), and high altitude adaptability (power loss of only 16% at 5000 meters altitude). In addition, the engines are small in size, low in noise, and have fast cold starts, enjoying an extremely high reputation in the global small and medium power industrial diesel engine market.
4. Q: What is the typical maintenance cycle for Volvo generators?
A: Volvo has a four-level maintenance system:
A-level maintenance (every 250 hours or 1 month): Change engine oil and oil filter, clean air filter.
B-level maintenance (every 500 hours or 3 months): Change fuel filter and water filter, check drive belt.
C-level maintenance (every 1000-2000 hours): Clean cooling system, check fuel injectors and turbocharger.
D-level maintenance (as needed): Full engine overhaul. The first maintenance is required after 50 hours of operation. For generator sets on long-term standby, maintenance every six months or one year is sufficient, but a 5-10 minute no-load test run should be performed monthly.